User Manual

AT75C220
133
SPI Interrupt Enable Register
Register Name:SP_IER
Access Type:Write-only
RDRF: Receive Data Register Full Interrupt Enable
0 = No effect.
1 = Enables the receiver data register full interrupt.
TDRE: SPI Transmit Data Register Empty Interrupt Enable
0 = No effect.
1 = Enables the transmit data register empty interrupt.
MODF: Mode Fault Error Interrupt Enable
0 = No effect.
1 = Enables the mode fault interrupt.
OVRES: Overrun Error Interrupt Enable
0 = No effect.
1 = Enables the overrun error interrupt.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
––––OVRES MODF TDRE RDRF