Manual
605
6264A–CAP–21-May-07
AT91CAP9S500A/AT91CAP9S250A
36.8.7 SSC Receive Holding Register
Name: SSC_RHR
Access Type: Read-only
• RDAT: Receive Data
Right aligned regardless of the number of data bits defined by DATLEN in SSC_RFMR.
36.8.8 SSC Transmit Holding Register
Name: SSC_THR
Access Type: Write-only
• TDAT: Transmit Data
Right aligned regardless of the number of data bits defined by DATLEN in SSC_TFMR.
31 30 29 28 27 26 25 24
RDAT
23 22 21 20 19 18 17 16
RDAT
15 14 13 12 11 10 9 8
RDAT
76543210
RDAT
31 30 29 28 27 26 25 24
TDAT
23 22 21 20 19 18 17 16
TDAT
15 14 13 12 11 10 9 8
TDAT
76543210
TDAT