Owner manual

14
ATF1508AS(L)
0784O–PLD–09/02
Notes: 1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. I
CC3
refers to the current in the reduced-power mode when macrocell reduced-power is turned ON.
DC and AC Operating Conditions
Commercial Industrial
Operating Temperature (Ambient) 0°C - 70°C -40°C - 85°C
V
CCINT
or V
CCIO
(5V) Power Supply 5V ± 5% 5V ± 10%
V
CCIO
(3.3V) Power Supply 2.7V - 3.6V 2.7V - 3.6V
DC Characteristics
(1)
Symbol Parameter Condition Min Typ Max Units
I
IL
Input or I/O Low
Leakage Current
V
IN
=V
CC
-2 -10 µA
I
IH
Input or I/O High
Leakage Current
210µA
I
OZ
Tri-state Output
Off-state Current
V
O
=V
CC
or GND -40 40 µA
I
CC1
Power Supply
Current, Standby
V
CC
=Max
V
IN
=0,V
CC
Std Mode Com. 160 mA
Ind. 180 mA
“L” Mode Com. 10 µA
Ind. 10 µA
I
CC2
Power Supply Current,
Power-down Mode
V
CC
=Max
V
IN
=0,V
CC
“PD” Mode 1 10 mA
I
CC3
(2)
Reduced-power Mode
Supply Current
V
CC
=Max
V
IN
=0,V
CC
Std Mode Com. 65 mA
Ind. 85 mA
V
CCIO
Supply Voltage
5.0V Device Output Com. 4.75 5.25 V
Ind. 4.5 5.5 V
V
CCIO
Supply Voltage 3.3V Device Output 3.0 3.6 V
V
IL
Input Low Voltage -0.3 0.8 V
V
IH
Input High Voltage 2.0 V
CCIO
+0.3 V
V
OL
Output Low Voltage (TTL)
V
IN
=V
IH
or V
IL
V
CCIO
=MIN,I
OL
=12mA
Com. 0.45 V
Ind. 0.45 V
Output Low Voltage (CMOS)
V
IN
=V
IH
or V
IL
V
CC
=MIN,I
OL
=0.1mA
Com. 0.2 V
Ind. 0.2 V
V
OH
Output High Voltage (TTL)
V
IN
=V
IH
or V
IL
V
CCIO
=MIN,I
OH
=-4.0mA
2.4 V