Owner manual

DS1720
030598 7/12
DS1720 COMMAND SET Table 3
INSTRUCTION DESCRIPTION PROTOCOL
3–WIRE BUS
DATA AFTER
ISSUING
PROTOCOL
NOTES
TEMPERATURE CONVERSION COMMANDS
Read Temperature Reads last converted temperature
value from temperature register
AAh <read data>
Read Counter Reads value of count remaining from
counter
A0h <read data>
Read Slope Reads value of the slope accumulator A9h <read data>
Start Convert T Initiates temperature conversion EEh Idle 1
Stop Convert T Halts temperature conversion 22h Idle 1
THERMOSTAT COMMANDS
Write TH Writes high temperature limit value into
TH register
01h <write data> 2
Write TL Writes low temperature limit value into
TL register
02h <write data> 2
Read TH Reads stored value of high tempera-
ture limit from TH register
A1h <read data> 2
Read TL Reads stored value of low temperature
limit from TL register
A2h <read data> 2
Write Config Writes configuration data to configura-
tion register
0Ch <write data> 2
Read Config Reads configuration data from configu-
ration register
ACh <read data> 2
NOTES:
1. In continuous conversion mode, a Stop Convert T command will halt continuous conversion. To restart, the Start
Convert T command must be issued. In one–shot mode, a Start Convert T command must be issued for every
temperature reading desired.
2. Writing to the E
2
typically requires 10 ms at room temperature. After issuing a write command, no further writes
should be requested for at least 10 ms.