3.1.1.1 Selecting PB storage active
Send command
AT+CPBS=<PB><cr>
where:
<PB> is the desired PB storage:
SM SIM phonebook
FD fixed dialing phonebook
LD last dialed calls list
MC – missed calls list
RC received calls list
wait for response:
Response Reason Action
OK selected PB is now active Proceed ahead
ERROR some error occurred Enable extended result codes
(see par. 2.5.2.1)
and retry.
+CME ERROR: 10 SIM not present Check SIM or require SIM
insertion and repeat from par.
2.5.2.2
+CMS ERROR: 310 SIM not present Check SIM or require SIM
insertion and repeat from par.
2.5.2.2
+CME ERROR: 11 SIM is present and PIN is
required to continue operations
insert SIM PIN (see par.
2.5.2.3)
+CMS ERROR: 311 SIM is present and PIN is
required to continue operations
insert SIM PIN (see par.
2.5.2.3)
+CME ERROR: 12 SIM is present and PUK is
required to continue operations
insert SIM PUK (see
par.2.5.2.4)
+CMS ERROR: 316 SIM is present and PUK is
required to continue operations
insert SIM PUK (see
par.2.5.2.4)
+CME ERROR: 13 SIM defect Check SIM insertion or require
a new SIM not defected and
repeat from par. 2.5.2.2
+CMS ERROR: 313 SIM defect Check SIM insertion or require
a new SIM not defected and
repeat from par. 2.5.2.2
+CME ERROR: 14 SIM is busy retry later
+CMS ERROR: 314 SIM is busy retry later
+CME ERROR: 15 SIM is wrong type Check SIM, it must be a GSM
SIM.
+CMS ERROR: 315 SIM is wrong type Check SIM, it must be a GSM
SIM.
+CME ERROR: 17 PIN2 is required to continue
operations, since FD facility is
not enabled.
Enable FD facility with +CLCK
(see par.3.1.1.2)
and retry.