2- Let's assume you have the IRA code 0x6B and you want to find the corresponding character:
From the table you find at the position
- most significant Nibble: 6
- least significant Nibble: B
Hence, the character corresponding to the 0x6B IRA code is 'k'.
TIP: With the command AT+CSCS is possible to select the character set; the available types
are:
“IRA” - ITU-T.50
”8859-1” - ISO 8859 Latin 1
”PCCP437” - PC character set Code Page 437.
”UCS2” - 16-bit universal multiple-octet coded character set (ISO/IEC10646)
Please refer to the AT Commands Reference Guide for the full command description
3.5.3 Writing a New SMS to storage
A new SMS can be written in the selected storage <memw> (in the current SW version only "SM" is
supported) and then can be sent to the desired destination.
To write the new SMS:
•
send command
AT+CMGW="<da>"<cr>
where:
<da>: destination address
• wait for prompt "
>
"
• send SMS text (MAX 160 characters)
• end command with CTRL-Z character (0x1A hexadecimal) or abort command with ESC character
(0x1B hexadecimal)
• wait for response:
Response Reason Action
+CMGW: <index>
OK
Message has been successfully
written in position number
<index>
proceed ahead
ERROR some error occurred Enable the extended error
codes report (see par.2.5.2.1)
and retry.
+CMS ERROR: 330 SMSC address unknown Insert SMSC address (see par.
3.5.1.3)
+CMS ERROR: 322 Memory Full memory is full, hence delete
some records and retry.
NOTE: if command is aborted with ESC character, then only the OK result code is returned.