Owner manual

Functional Description (Continued)
12.10 Value RAM — Address 20h–3Fh
Address A7–A0 Description
20h IN0 reading
21h IN1 reading
22h IN2 reading
23h IN3 reading
24h IN4 reading
25h IN5 reading
26h IN6 reading
27h Temperature reading
28h FAN1 reading
Note: This location stores the number of counts of the internal clock per revolution.
29h FAN2 reading
Note: This location stores the number of counts of the internal clock per revolution.
2Ah IN0 High Limit
2Bh IN0 Low Limit
2Ch IN1 High Limit
2Dh IN1 Low Limit
2Eh IN2 High Limit
2Fh IN2 Low Limit
30h IN3 High Limit
31h IN3 Low Limit
32h IN4 High Limit
33h IN4 Low Limit
34h IN5 High Limit
35h IN5 Low Limit
36h IN6 High Limit
37h IN6 Low Limit
38h Hot Temperature Limit (High)
39h Hot Temperature Hysteresis Limit (Low)
3Ah OS Temperature Limit (High)
3Bh OS Temperature Hysteresis Limit (Low)
3Ch FAN1 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit of the fan speed.
3Dh FAN2 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit of the fan speed.
3Eh-3Fh Reserved
Note: Setting all ones to the high limits for voltages and fans (0111 1111 binary for temperature) means interrupts will never be generated except the case when
voltages go below the low limits.
For voltage input high limits, the device is doing a greater than comparison. For low limits, however, it is doing a less than or equal to comparison.
LM80