Instruction Manual
MAX16064
±0.3% Accurate, Quad, Power-Supply Controller with
Active-Voltage Output Control and PMBus Interface
______________________________________________________________________________________ 23
MAX16064 Address Assignment
The MAX16064 picks a slave address in one of the two
ways described below:
1) Hardwired by A3:A2:A1.
2) Restored from EEPROM at power-on.
Address assignment order is shown in Figure 10.
The MAX16064 reads A3:A2:A1 address pins upon
device reset and determines its address according to
Table 3.
RESET
t
ON0
t
RP
t
OFF0
t
ON1
t
OFF1
t
OFF2
t
OFF3
t
ON2
t
ON3
ENOUT3
ENOUT2
ENOUT1
ENOUT0
EN
NOTE: MFR_RESET_OUTPUT = 3
Figure 9. MAX16064 Typical Sequencing Timing
Table 3. MAX16064 A3:A1 Slave Address Assignment
A3/CONTROL A2/SDAE A1/SCLE ADDRESS (BITS 7–1)
L L L 40h
LLZ 01h*
LZL 02h
LZZ 03h
ZLL 04h
ZLZ 05h
ZZL 06h
ZZZ 07h
L L H 09h
LZH 0Bh
ZLH 0Dh