User Manual
MAX4881–MAX4884
Overcurrent Flag Output (
FLAGI
)
The MAX4881–MAX4884 have an overcurrent-fault flag
output (FLAGI) to indicate a current fault condition.
FLAGI asserts low to indicate a fault when the current
reaches the current limit for longer than the 50ms blank-
ing time. Toggle IN or CB or EN to release FLAGI latched
condition. FLAGI does not assert if the current-limit fault
occurs for less than the blanking time (Figure 5).
FLAGI is disabled when EN goes high. When CB is low,
the switch opens, but FLAGI is not active.
FLAGI is an open-drain active-low output. Connect a
pullup resistor from FLAGI to the logic I/O voltage of the
host system, or to any voltage source up to 6V.