Owner manual
9
TH7899M
2201A–IMAGE–02/02
34
12
Mode 13
A3 4
12
Mode 14
B
34
12
Mode 15
34
12
Mode 16
34
12
Mode 17
34
12
Mode 18
Only when using specific device with optical shield (on request)
F LA1=F LA3=F LA5=F L1
MODES 14-15-16-17-18 :
MODES 13-15-16-17-18 :
F LA2=F LA4=F LA6=F L2
F LB1=F LB4=F LB6=F L1
F LB2=F LB3=F LB5=F L2
hnb=1054
1054 PIXEL PERIODS
34
12
Mode 2
A3 4
12
Mode 4
B
34
12
Mode 6
34
12
Mode 8
34
12
Mode 10
34
12
Mode 12
F LA1=F LA3=F LA6=F L1
MODES 4-6-8-10-12 :
MODES 2-6-8-10-12 :
F LA2=F LA4=F LA5=F L2
F LB1=F LB3=F LB6=F L1
F LB2=F LB4=F LB5=F L2
hnb=2078
2078 PIXEL PERIODS
34
12
Mode 1
A3 4
12
Mode 3
B
34
12
Mode 5
34
12
Mode 7
34
12
Mode 9
34
12
Mode 11
F LA1=F LA4=F LA5=F L1
MODES 3-5-7-9-11 :
MODES 1-5-7-9-11 :
F LA2=F LA3=F LA6=F L2
F LB1=F LB4=F LB5=F L1
F LB2=F LB3=F LB6=F L2
hnb=2078
2078 PIXEL PERIODS
F PA 1= F PB1=F PC1=F PD1=F A
MODES 1-2-13 :
F PA 2= F PB2=F PC2=F PD2=F B
F PA 3= F PB3=F PC3=F PD3=F C
F PA 4= F PB4=F PC4=F PD4=F D
F TA=Low level
F TB=F A
vnb=2080
2080 TRANSFERS MINIMUM
F PA 1= F PB1=F PC1=F PD1=F A
MODES 3-4-14 :
F PA 2= F PB2=F PC2=F PD2=F D
F PA 3= F PB3=F PC3=F PD3=F C
F PA 4= F PB4=F PC4=F PD4=F B
F TA=F A
F TB=Low level
vnb=2080
2080 TRANSFERS MINIMUM
F PA 1= F PB1=F PC1=F PD1=F A
MODES 5-6-15 :
F PA 4= F PB4=F PC2=F PD2=F B
F PA 3= F PB3=F PC3=F PD3=F C
F PA 2= F PB2=F PC4=F PD4=F D
F TA=F A
F TB=F A
vnb=1040
1040 TRANSFERS MINIMUM
F PA 1= F PB1=F PC1=F PD1=F A
MODES 7-8-16 :
F PA 4= F PB2=F PC2=F PD2=F B
F PA 3= F PB3=F PC3=F PD3=F C
F PA 2= F PB4=F PC4=F PD4=F D
F TA=F A
F TB=F A
vnb=1560
1560 TRANSFERS MINIMUM
HORIZONTAL TRANSFERS
VERTICAL TRANSFERS
F PA1=F PB1=F MA
MODES 9-10-17 :
F PC1=F PD1=F PA
F PA3=F PB3=F MC
F PC3=F PD3=F PC
F PA4=F PB4=F MB
F TA=F MA
F TB=F PA (or low level)
vnb=1040
1040 TRANSFERS MINIMUM
F PC4=F PD4=F PB
F PA2=F PB2=F MD
F PC2=F PD2=F PD
F PA1=F PD1=F MA
MODES 11-12-18 :
F PC1=F PB1=F PA
F PA3=F PD3=F MC
F PC3=F PB3=F PC
F PA4=F PD2=F MB
F TA=F MA
F TB=F MA
vnb=520
520 TRANSFERS MINIMUM
F PC2=F PD4=F PB
F PA2=F PD4=F MD
F PC4=F PB2=F PD
F A, F B, F C, and F D correspond to the clocks
described in the timing diagram page 10 in
case of full frame timing.
F PA , F PB, F PC, F PD, F MA, F MB, F MC, F MD
correspond to the clocks described in the
timing diagram page 13 in case of frame
transfer timing with memory zone.
F L1, F L2, correspond to the clocks described
in the timing diagram page 10.
vnb and hnb are respectively the vertical
transfer number and the horizontal transfer
number which shall be repeated in the timing
diagram described page 10.
The unused horizontal clocks (F L, F S, F R)
shall be stated to their high level.
Main Operating Modes and Selection Table for Vertical Transfer Number (vnb) and for Horizontal
Transfer Number (hnb)