Instruction Manual
W90P710CD/W90P710CDG
Publication Release Date: September 19, 2006
- 119 - Revision B2
BITS DESCRIPTIONS
[31:0] Length/Type
Length/Type Field of PAUSE Control Frame
In the PAUSE control frame, a length/type field is
defined and will be 16’h8808.
[15:0] OP-Code
OP Code Field of PAUSE Control Frame
In the PAUSE control frame, an op code field is defined
and will be 16’h0001.
CAM15L
31 30 29 28 27 26 25 24
Operand (MSB)
23 22 21 20 19 18 17 16
Operand
15 14 13 12 11 10 9 8
Reserved
7 6 5 4 3 2 1 0
Reserved
BITS DESCRIPTIONS
[31:16] Operand
Pause Parameter, In the PAUSE control frame, an operand field is
defined and controls how much time the destination Ethernet MAC
Controller is paused. The unit of the operand is the slot time, the 512
bits time.
[15:0] Reserved