User manual
US English User Manual RAIS X-Basic, RAIS X-Front & RAIS X-Board
32
Ref. Description Minimum clearence
A Sidewall to unit
16” (48.3 cm)
B Backwall to unit
15” (38.1 cm)
C Cornerwall to unit
4” (10.2 cm)
D Sidewall to connector
31.5” (80 cm)
E Backwall to connector
19” (48.3 cm)
F Cornerwall to connector
18” (45.7 cm)
G Ceiling to appliance
36” (91.4 cm)
H Backwall to unit
-
I Backwall to connector
-
J Sidewall to unit
-
K Sidewall to connector
-
L Distance to frontwall/furnishing
-
M Cornerwall to connector
-
Clearance to combustible walls
To nd out whether the wall by which the stove is to be placed is combustible or not,
please contact your architect or the local building authorities.
If the oor is combustible, the stove must be placed on a non-combustible plate such as
steel, glass or stone.