Ref. Description Minimum clearence
A Sidewall to unit
16” (48.3 cm)
B Backwall to unit
15” (38.1 cm)
C Cornerwall to unit
4” (10.2 cm)
D Sidewall to connector
31.5” (80 cm)
E Backwall to connector
19” (48.3 cm)
F Cornerwall to connector
18” (45.7 cm)
G Ceiling to appliance
36” (91.4 cm)
H Backwall to unit
-
I Backwall to connector
-
J Sidewall to unit
-
K Sidewall to connector
-
L Distance to frontwall/furnishing
-
M Cornerwall to connector
-
Clearance to combustible walls
To nd out whether the wall by which the stove is to be placed is combustible or not,
please contact your architect or the local building authorities.
If the oor is combustible, the stove must be placed on a non-combustible plate such as
steel, glass or stone.