 LX/LX3 User Guide Rajant Corporation
Version: 2.91 03-100101-001
Table 7: Status LED Color Codes.
Color Status
Solid Red Booting
Blinking Red   
1
   Error
Solid Blue Ready, but no peers
Solid Green At least one 24 Mbps or higher peer
Blinking Green At least one peer
Blinking Yellow
(at a constant rate)
Progress
Blinking Yellow   
1
(with short and long pauses between blinks)
Warning
All Status LED colors scrolling in succession Success/Completion
 1.3.6  Zeroize Keys and Restore Factory Defaults / LED Configuration 
Switch 
The Zeroize Keys and Restore Factory Defaults / LED Configuration Switch (see Figure 3) has two 
modes of operation. The modes are set by the length of time the switch is asserted. The modes are:
• Zeroize Keys and Restore Factory Defaults
• LED Configuration
 1.3.6.1  Zeroize Keys and Restore Factory Defaults
This mode is is used to erase the security protocol keys of a BreadCrumb LX/LX3 and to restore its 
software configuration to the factory default state. To operate this switch follow these procedures:
• Ensure that the BreadCrumb is powered on, has fully booted-up and its Status LED (see 
Figure 3) color is green or blue (see Table 7).
• Press the switch and hold the switch for approximately 10 seconds until the Status LED 
changes to the error indicator of blinking red. See code 32 in Appendix A for a description 
of the blinking red color sequence.
• Release the switch. The BreadCrumb will then reboot using the factory default configuration.
1 For a list of error and warning codes refer to Appendix A at the end of this document.