Table 6: Status LED Color Codes.
Color Status
White
(red, green and blue LEDs together;
may appear pale blue or pale green)
Powered, prior to Booting
Solid Red Booting
Blinking Red
1
Error
Solid Blue Ready, but no peers
Solid Green At least one 24 Mbps or higher peer
Blinking Green At least one peer
Blinking Yellow
(at a constant rate)
Progress
Blinking Yellow
1
(with short and long pauses between blinks)
Warning
All Status LED colors scrolling in succession Success/Completion
2.6 LED Configuration / Zeroize Keys and Restore Factory Defaults
Switch
The LED Configuration / Zeroize Keys and Restore Factory Defaults Switch (see Figure 3) has two
modes of operation. The modes are set by the length of time the switch is asserted. The modes are:
LED Configuration
Zeroize Keys and Restore Factory Defaults
2.6.1 LED Configuration
This mode is used to control the display states of the Status LED. The LED Configuration function
is accessed by pressing the switch and releasing it after a two second hold. The configured display
state of the Status LED is dictated by the LED Mode setting that is configured from BC|Commander
(please refer to the BC|Commander User Guide for a more detailed description of the LED Mode
setting). The user can toggle between the configured state and an alternate state of the Status LED
by pressing the switch and activating the LED Configuration function.
Table 7 lists the possible configured and corresponding alternate display states of the Status LED.
1 For a list of error and warning codes refer to Appendix A at the end of this document.
13