User guide

24
BASIC OPERATION
2.06.06 Generating Two-Tone Paging Signals (Continued)
You wish to generate a typical two-tone, tone only paging signal. Tone one is 349.0 Hz, and
tone-two is 433.7 Hz.
Sets tone one to 349 Hz.
Sets tone two to 433.7 Hz.
Sets tone deviation level to 3.5 kHz. (Default level is 4 kHz and does not need to be entered
if default level is suitable)
Sets two-tone, tone only mode (third mode).
Sends the tone sequence.
It is not necessary to change all fields every time; typically you will only need to change the
two tones and send.
Two tone uses its own deviation setting. It will not affect the internal setting.
As an added feature, CTS tones can be generated at the same time as two-tone pages for ra-
dios that require a Two-Tone signal to open the squelch, and a CTS tone to keep the squelch
open. Simply turn on the CTS mode and select the required tone (see generating CTS tones)
before sending the Two-Tone page.
GENERATE TX Level
Modulation Seq/Reg
RECEIVE Level Meters
Counter Freq Meters