HYDRAULIC SYSTEM REQUIREMENTS
Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of: (1) line pull (LB) first layer vs. working pressure (PSI) and (2) line speed, first layer (FPM) vs.
flow (GPM). STATIC (solid line) refers to hoisting a suspended load from rest; DYNAMIC (dotted line) refers to
maintaining the motion of a moving load. A cylinder spool directional control valve is recommended.
*CAUTION: DO NOT EXCEED 20 GPM. IF EXCEEDED, MOTOR AND WINCH MAY BE DAMAGED.
PERFORMANCE CHARTS
SYSTEM REQUIREMENTS:
2100 PSI RELIEF VALVE SETTING
15 GPM FLOW RATE*
10 MICRON NOMINAL FILTRATION
WORKING PRESSURE, PSI
LINE PULL, LBS.
FIRST LAYER
LINE SPEED, FPM
FIRST LAYER
FLOW, GPM
* BRAKE CAPACITY: 8000 LBS.
PERFORMANCE WITH 24.9 CU. IN. HYDRAULIC MOTOR