Installation Guide
Install of The Compact Panel Cassette Type Indoor Unit
2
2 Install of The Compact Panel Cassette Type Indoor Unit
2.1 Schematic diagram of installation spaces
≥
98 (
2500
)
≥59(1500)
≥59(1500)
Model
 H
unit: in (mm)
>
0.75(
20
)
Wall
surface
Wall
surface
Wall
surface
Ground
surface
H
CH12CC230VI
CH18CC230VI
Fig.1
2.2 Select install location of the indoor unit
(1). Obstruct should put away from the intake or outlet vent of the indoor unit so that the airow 
can be blown though all the room.
(2). Make sure that the installation had accord with the requirement of the schematic diagram of 
installation spaces.
(3). Select the place where can stand 4 times of the weight of the indoor unit and would not 
increase the operating noise and oscillate.
(4). The horizontally of the installation place should be guaranteed.
(5). Select the place where easy drain condensated coagulated water, and easy connect with 
outdoor unit.
(6). Make sure that there are enough space for care and maintenance. Make sure that the 
weight between the indoor unit and ground is above 98in (2500mm).
(7). When installing the steeve bolt, check if the install place can stand the weight 4 times of the 
unit’s. If not, reinforce  before installation.  (Refer to  the install  cardboard and  nd where  should be 
reinforced)
Note!
There will be lots of lampblack and dust stick on the acentric, heat exchanger and water pump 
in dining room and kitchen, which would reduce the capacity of heat exchanger, lead water leakage 
and abnormal operation of the water pump. The following treatment should be taken under this 
circumstance:
(8). Ensure that the smoke trap above cooker has enough capacity to obviate lampblack to 
prevent the indraft of the lampblack by the air conditioner.
(9). Keep the air conditioner far from the kitchen so that the lampblack would not be indraft by 
the air conditioner.
10 (270)
 10 (260)
CH24CC230VI