RANCO®
ICE MACHINE CONTROLS
A30 SERIES DIRECT REPLACEMENT, CONSTANT DIFFERENTIAL AND CONSTANT CUT-IN CONTROLS
Direct replacement constant differential or constant cut-in cold controls.
Used on commercial refrigerators, freezers, ice machines, vending
machines, beverage coolers, and water coolers.
Controls have SPST switching with “Off position unless noted.
ELECTRICAL RATING
RATING 24V 120V 240V 277V
AC FULL LOAD AMPS - 20 20 16
AC LOCKED ROTOR AMPS - 80 80 60
PILOT DUTY (VA) 240 240 240 240
RESISTIVE LOADS AMPS - - - 16
WARM/COLD
PART NO TYPE OF ADJUST DIFF OFF ON -ON -OFF CAP BULB OEM OEM P/N
RAN-A30-323 DIAL 10 -5 5 10.5 -11 48 -- -- --
RAN-A30-542 DIAL 15 10 25 41.5 1 27 -- -- --
RAN-A30-543 DIAL 12 15 27 55 7 27 -- -- --
RAN-A30-544 DIAL 15 10 25 43 1 72 -- -- --
RAN-A30-1769 DIAL 7 -7 0 10 -19 36 -- TRAULSEN 12769
RAN-A30-1819 DIAL 7 18 25 37 12 24 -- MATTHIESEN --
RAN-A30-1977 SCREWDRIVER 10 14 24 30 5 24 -- STAR COOLER (HUSSMANN) 0308352
RAN-A30-2209 DIAL 8 36.5 44.5 46 35 48 -- -- --
RAN-A30-2210 DIAL 8 32 40 42 30 48 -- -- --
RAN-A30-2211 DIAL 10 0 10 17.5 -10.5 48 -- -- --
RAN-A30-2212 SCREWDRIVER 6 47 53 57 42.5 48 -- -- --
RAN-A30-2282 DIAL 5 43 48 58 32 48 -- TRAULSEN 36989-00
RAN-A30-3618 DIAL 17 23 40 45 17 30 -- BEV AIR 502-014A
RAN-A30-3620 DIAL 24 16 40 43 12 30 -- BEV AIR P502-48AB
RAN-A30-3723 SCREWDRIVER 14 26 40 44 21 18 -- -- --
RAN-A30-3725 SCREWDRIVER 19 24 43 50 16 60 3/8D GLENCO/STAR SP-64-35B
RAN-A30-3734 DIAL 11 -18 -7 17 -32 72 -- HUSSMANN SELF CONTAINED 4-S-28
RAN-A30-3737 DIAL 9 -8 1 12 -22 36 3/8D HUSSMANN/VICTORY 50616101
RAN-A30-3755 SCREWDRIVER 13 28 41 47 20 24 -- TAYLOR 27505
RAN-A30-3769 SCREWDRIVER 16 32 48 55.5 22 18 -- -- --
A12 SERIES CONSTANT CUT-IN CONTROL
The Ranco A12 Controls provide a constant Cut-In feature. The constant Cut-
In design is generally used to provide an Off-Cycle defrost function. Each time
the control cycles off, the control contacts will remain “open” until the
evaporator is cleared of any frost that may have accumulated from the previou
s
On” Cycle. The A12 constant Cut-In setting will be between 35° and 41° F.
(See Control Chart.)
Generally, medium refrigeration units without hot gas or electric defrost systems
will use a Constant Cut-In Control (A12 Series).
Rotating the Knob/Dial changes only the Cutout setting. The Cut-In setting
remains the same regardless of the Knob/Dial position.
PART NO NORMAL OFF (°F) WARM OFF (°F) COLD OFF (°F) CUT-IN CONSTANT (°F) CAPILLARY LENGTH (in)
RAN-A12-1506 15 22 9 38 39 x 3/8 x 1-3/8
RAN-A12-700 18 26 11.5 37 84
RAN-A12-710 23 27 19 36.5 21 x 3/8 x 1-3/8
RAN-A12-701 23.5 31 15 41 84
RAN-A12-1560 24 29 19 38 72
RAN-A12-711 18.5 23 14 37 31 x 3/8 x 1-3/8
RAN-A12-712 15.5 23 8 35 79