Operator`s manual

24
2424
24
888-994-7636
FX1- 4N1 Control Operation con’t
HOW TO SET THE CYCLE OF OPERATION
TO CHANGE THE CYCLE: Press and hold the START/STOP key until the yellow LED turns off.
HOW TO SELECT A CYCLE: Press the key until the desired cycle is selected. (See FIGURE-C
for example of display and description of cycles.)
HOW TO START A CYCLE: Press the START/STOP key. The correspondent yellow LED is
switched on.
HOW TO STOP A CYCLE: Press and hold the START/STOP key until the yellow LED turns off.
HOW TO SET THE TEMPERATURE WITHIN EACH CYCLE OF OPERATION
SETTING THE TEMPERATURES IN THIS MANNER IS TEMPERARY AND WILL REVERT TO STANDARD
TEMPERATURE SETTINGS WHEN THE CYCLE IS CHANGED
(Temperature set points can be changed in cycles & H (HOLD) only)
TO CHANGE THE TEMPERATURE SETTING FOR CYCLES & :
Follow the instructions HOW TO SET THE CYCLE OF OPERATION to set the cycle required.
Once this is set perform the following steps.
Press the SET key the symbol in yellow LED will be displayed.
Press and hold the SET key until the LED and the yellow LED light on the SET key
left top corner is blinking.
Press the UP key to raise the temperature.
Press the DOWN key to lower the temperature.
Temperature on the display will change either by pushing the key one increment at a time or by
holding down the key to quickly scroll through the numbers.
Once the temperature is selected press the SET key to confirm and activate this new
setting.
1
2
1
2