OPERATOR’S MANUAL This manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for CHICK-FIL-A REFRIGERATED BREADING TABLE 52365WPRM-CFA NOTIFY CARIER OF DAMAGE AT ONCE. It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Randell suggests that if you are suspicious of damage to make a notation on the delivery receipt.
Table of Contents page 2………………………………….…………Congratulations page 3……………………………………Parts & Service Hotline page 3………………………………...…Serial Number Location page 4-7……………………………….Randell Limited Warranty page 8…………………………………………Unit Specifications page 9……………………………………….........Unit Installation page 10-12....……………………………………...Unit Operation page 13-15……………………………..Preventive Maintenance page 16………………………………………..Electrical Diagram page 17……………………………………..……Troubleshooting page 18-20…………………………….……..
In addition, all Randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians. Retain this manual for future reference. NOTICE: Due to a continuous program of product improvement, Randell reserves the right to make changes in design and specifications without prior notice. NOTICE: Please read the entire manual carefully before installation.
Unit Specifications 52365WPRM-CFA Model 52365WPRM-CFA 8 L D H Work Hgt. Doors H.P. Volts Amps NEMA Cubic Volume Ship Wt. 65" 33" 41.25" 38.5" 3 1/2 115 10 5-15P 52.
Unit Installation SELECTING A LOCATION FOR YOUR NEW UNIT The following conditions should be considered when selecting a location for your unit: 1. Floor Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit plus the maximum product load weight. All casters must be in contact with the floor to support the weight. Casters may require shims in order for the caster to be in contact with the floor.
Unit Operation UNIT INFORMATION Mechanical Compartment 1. The breading station is supplied with a main power switch. The switch is located on the rear of electrical box behind the upper hinged vented door. The main power switch will completely shut down the upper rail as well as the lower refrigerated base. 2. The rail power switch is located on the front of the electrical box. The rail power switch will shut down the rail for nightly shut down and cleaning.
Unit Operation - cont. MORNING STARTUP OF PREP RAIL 1. Unit cleaning may be performed at this time. 2. Turn on unit. Power switch for rail is found behind upper hinged vented door. 3. Allow a minimum 45 minutes for your unit to cool down before loading product. 4. Load the product and proceed with food preparation. Note: Product entering unit must be at 41°F or less. EVENING SHUT DOWN OF PREP RAIL 1. Remove product from unit at the end of the day’s preparation. 2. Turn off unit 3.
Unit Operation - cont. To raise temperature in the refrigerated rail: A. Push and hold the “set” button until 34 appears then release the “set” button. 34 is the current set point temperature. B. Push and release the up arrow 2 times until 36 is displayed. Push and release the “set” button one time. The new set point, 36, will flash 3 times and then will be locked in. To lower temperature in the refrigerated rail: A. Push and hold the “set” button until 34 appears and then release the “set” button.
Preventive Maintenance Randell strongly suggests a preventive maintenance program which would include the following monthly, weekly, and daily procedures: If a failure of the equipment is a direct result of any of the Preventative Maintenance guidelines being neglected, the repairs and parts replacements will not be covered under warranty. It is recommended that the customer contact the local Authorized Service Agent to provide a quote to perform periodic Preventative Maintenance.
3. Clean and disinfect drain lines and evaporator pan with a solution of warm water and mild detergent on a monthly basis. 4. Clean all gaskets on a weekly if not daily basis with a solution of warm water and a mild detergent to extend gasket life. 5. Clean the grease filter on a weekly if not daily basis with either hot water, mild detergent, or by cycling through a dishwasher. 6.
STEPS FOR REMOVING THE GREASE FILTER FOR CLEANING Step 1: Locate grease filter on the front of the condenser air in duct. Behind lower hinged vented door. Step 2: Locate finger hole opening to remove filter without the use of tools. Step 3: Insert finger and force filter upwards. Step 4: Filter should fall out in your hands. Step 5: Pull downwards to release the filter at the top. Step 6: Filter should fall out of the top holding bracket.
Electrical Diagram 16 800-621-8560
Trouble Shooting Guide SYMPTOM POSSIBLE CAUSE Unit doesn't run 1. 2. 3. 4. 5. 6. 7. 8. Unit short cycles 1. Condenser coil/filter dirty 2. Condenser fan faulty 3. Compressor faulty 4. Overload repeatedly tripping 5. Solenoid not seating 1. Clean coil/filter 2. Service fan and motor. 3. Call ASA for service 4. Check outlet voltage 5. Call ASA for service Unit runs constantly 1. Condenser coil/filter dirty 2. Condenser fan faulty 1. Clean coil/filter 2. Service condenser motor 3. Filter light on 1.
Replacement Parts Refrigerated Breading Tables CAUTION: Hold lid with both hands securely at all times during opening and closing.
unifiedbrands.
ITEM DESCRIPTION PART # 1 Hinged Cover with Recessed Handle RP PCR0501 2 Counter Balance Hinge Lift Assy HD HNG0501 3 Adapter Grid, 12” x 20” RP ADP0801 4 Drain Screen, 2” RP DSN002 5 Elbow, 1 ½” PVC Fem x Glue PB ELB9905 6 Pipe, 1 ½” PVC PB PIP150 7 Ball Valve, 1 ½” PVC Female PB VLV9901 8 Dixell Digital Control for Base RP CNT0204 9 Rocker On/Off Switch for Rail EL SWT0502 10 Dixell Digital Control for Rail RP CNT0501 11 Clean Condenser Indicator Light EL LGT0305 12 Lo
20 Temperature Control Probe - Dixell RF CNT0505 21 Evaporator Condensate Pan, Plastic RP DRP107 22 Expansion Valve RF VLV404 23 Shield Panel for Base Coil Assembly RP PNL107 24 Evaporator Coil Assembly RP CSY108SL 24A Evaporator Coil RF COI107 25 Solenoid Valve RF SOL9801 26 Evaporator Fan Shroud RP SHD107 27 Mounting Support Bracket for Base Coil Assembly RP SPT0500 28 Door Assembly with Toe Bracket, Right Hinge RP DOR0708 29 Door Assembly with Toe Bracket, Left Hinge RP DO