OPERATOR’S MANUAL This manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for 9900SCA Series / Drop-In Cold Pans NOTIFY CARIER OF DAMAGE AT ONCE. It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt.
Table of Contents page 2………………………………….…………Congratulations page 3……………………………………Parts & Service Hotline page 3………………………………...…Serial Number Location page 4-7……………………………….Randell Limited Warranty page 8…………………………………………Unit Specifications page 9-13.………………………………………...Unit Installation page 14-15..…………………………………..…..Unit Operation page 15-16.………………………..…Preventative Maintenance page 17………………………………………..Electrical Diagram page 18……………………………………..……Troubleshooting page 19-20…………………………….….....
In addition, all Randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians. Retain this manual for future reference. NOTICE: Due to a continuous program of product improvement, Unified Brands reserves the right to make changes in design and specifications without prior notice. NOTICE: Please read the entire manual carefully before installation.
Warranty Policies Unified Brands believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit comes the peace of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerances, by a manufacturer with over 30 years of industry presence.
Temperature adjustments are not covered under warranty, due to the wide range of ambient conditions. For warranty inquiries call our Field Service Department at: 1-800-621-8560. WHEN OPTIONAL 5 YEAR COMPRESSOR WARRANTY APPLIES 1. Provide reimbursement to an ASA for the cost of locally obtained replacement compressor in exchange for the return of the defective compressor sent back freight prepaid.
5. Insufficient service access openings in the counter/cabinet supplied by others. Lack of access could lead to increased repair times that exceed standard allowances. QUOTATIONS Verbal quotations are provided for customer convenience only and are considered invalid in the absence of a written quotation. Written quotations from Unified Brands are valid for 30 days from quote date unless otherwise specified. Unified Brands assumes no liability for dealer quotations to endusers.
In the event the item shows rough handling or visible damage to minimize liability, a full inspection is necessary upon arrival. Appearance of damage will require removing the crate in the presence of the driver. A notation must be placed on the freight bill and signed for by the truck driver at the time of delivery. Any and all freight damage that occurs to a Randell piece of equipment as a result of carrier handling is not considered under warranty, and is not covered under warranty guidelines.
Unit Specifications 9900SCA / 9900SCN – COLD PAN 12” X 20” Pan Capacity L 9918SCA 1 17 ½” 9928SCA 2 9943SCA Cutout Dim. HP Volt Amp. NEMA Ship Wt.
Unit Installation SELECTING A LOCATION FOR YOUR NEW UNIT The following conditions should be considered when selecting a location for your unit: 1. Countertop Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit plus the maximum product load weight. 2. Secure & Seal: Once the drop in unit is installed into the counter it can be secured to the countertop by using the brackets supplied from the factory.
Unit Installation (con’t) Cross ventilation in the cabinet is recommended to maintain ambient temperature 86°F or less. Avoid surrounding your drop in with other heat generating equipment and keep out of direct sunlight. Also, avoid locating in an unheated room or where the room temperature may drop below 55° F or above 86°F . It is recommended that drop in be installed with the condenser coil facing a ventilated opening in the cabinet.
NOTE: FAILURE TO FOLLOW INSTALLATION GUIDELINES RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT. AND ELECTRICAL SUPPLY: The wiring should be done by a qualified electrician in accordance with local electrical codes. A properly wired and grounded outlet will assure proper operation. Please consult the data tag attached to the compressor to ascertain the correct electrical requirements. Supply voltage and amperage requirements are located on the serial number tag located inside the mechanical housing.
12 800-621-8560
unifiedbrands.
Unit Operation Randell has preset the cold control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food product as well as type of operation, you may need to alter this temperature. Additional adjustments can be made (within limits) by turning the control dial up or down until the desired temperature is reached. Please allow 24 hours between adjustments. Your condiment pans will remain proper temperatures when utilized properly.
Unit Operation (con’t) EVENING SHUT DOWN 1. Remove product from the cold pan at the end of the day’s preparation. The product may be discarded or stored in any commercial refrigerator. 2. Turn off the cold pan with the switch located within the mechanical compartment. 3. Unit cleaning may be performed at this time once the frost has melted off the surface.
RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING: CLEANING AGENT COMMENTS Routine cleaning JOB Soap, ammonia, detergent Medallion Apply with a sponge or cloth Fingerprints and smears Arcal 20, Lac-O-Nu, Ecoshine Provides a barrier film Stubborn stains and discoloration Cameo, Talc, Zud, First Impression Rub in the direction of the polish lines Greasy and fatty acids, blood, burnt-on foods Easy-Off, Degrease It, Oven Aid Excellent removal on all finishes Grease and Oil Any
Electrical Diagram unifiedbrands.
Trouble Shooting Guide SYMPTOM Unit doesn't run Unit short cycles Unit runs constantly Unit too cold Unit noisy 18 POSSIBLE CAUSE PROCEDURE 1. No power to unit 2. Temperature control turned off 3. Temperature control faulty 4. Compressor overheated 5. Condenser fan faulty 6. Overload protector faulty 7. Compressor relay faulty 8. Compressor faulty 1. Condenser coil dirty 2. Condenser fan faulty 3. Compressor faulty 4. Overload repeatedly tripping 1. Condenser coil dirty 2. Condenser fan faulty 3.
Replacement Parts 9900SCA Series unifiedbrands.
Replacement Parts Item # 9900SCA Series Part Number Part Description HD PIN001 PIN, KEY PAN RAIL NS PB VLV1000 DRAIN VALVE, 1" THREAD GATE* 3 RP CLP0102 HOLD DOWN CLIP COLD PANS AND PLATE CHILLERS 4 RP BRK013 CLIPS, PAN RAIL 9918SCA 4a RP BRK027 CLIPS, PAN RAIL 9928SCA 4b RP BRK019 CLIPS, PAN RAIL 9943SCA 1 1/2DIAx1/4, 1/4-20x3/8SHNK 4c RP BRK026 CLIPS, PAN RAIL 9957SCA 4d RP BRK032 CLIPS, PAN RAIL 9972SCA 4e RP BRK025 CLIPS, PAN RAIL 9986SCA 5 RP BAR0100 ADAPTER BAR
unifiedbrands.