Maintenance
Your braising pan is designed to require minimum maintenance, but certain parts 
may need replacement after prolonged use. After installation, no user adjustment 
should be necessary. If a service need arises, only authorized personnel should 
perform the work.
Service personnel should check the unit at least once a year. This periodic main-
tenance should include inspecting electrical wires and connections, cleaning the 
inside of the control console, and possible adjustment of the pilot light. (Units with 
standing pilot ignition only) At least twice a year, grease the two trunnion bearings 
and worm gear.
We recommend the use of number two grade LGI lithium grease. Add grease through 
the zerk fittings on the gear hosing until grease flows out of the bearings around trun-
nion shaft. Also, add grease in the gear to cover arc that is in contact with the worm 
gear. Clean up excess grease.
A Service Log is provided with the warranty information at the back of this manual. 
Each time service is performed on your equipment, enter the date on which the work 
was done, what was done, and who did it. Keep the manual with the equipment for 
quick and easy reference.