RECOMMENDED CALIBRATION PROCEDURE
e CP 64 is a very versatile instrument. While this allows it to conform to the requirements of a large number of system appli-
cations, it also results in complexity. For this reason, it is very important to use an organized approach to system calibration. Once
the internal switches are set and the system is connected, take the time for proper calibration. e following is an ordered list of
system adjustments that should make calibration easy and result in optimum performance. Most important:
• Program Priority Assign is set to Off
• Ducker is Off
• Zone Limit reshold is set to +20 dBu
• Page Zone Levels are set to minimum
• Remote Control is not selected
• Page Zone Assign is set to Both
e following procedure assumes that microphones are used for Page sources. e procedure (except for the exact wording) is the
same for other Page sources.
Make sure the POWER is off!
Control Presets:
Page settings (repeat for second page input):
• Input Pad Mic/Line as required
• Input gain trim Center (12:00)
• Detector reshold Min (ccw, Active)
• Paging assign Both
• Paging Level, Zone 1 Min
• Paging Level, Zone 2 Min
• Phantom Power As required. Default Off (internal)
• Pre/Post summing As required. Default Pre-VCA (internal)
• Page Priority As required. Default Page 1 (internal)
Program Input settings:
• Input Level controls Min
• Program Priority Input reshold Set to -50 at factory (internal adjust -∞ to -35 dBu)
• Program Priority Input Release Time Set to 12 sec. at factory (internal adjust 2 to 20 sec.)
• Program Priority Assign Off
Zone Settings (repeat for second zone):
• Zone Level Max
• Program Select L1 (if your input is on L1).
• Ducker OFF
• Ducker Depth Center (about 15 dB)
• RMT (Remote) Out (front panel)
• EQ Flat (center detent position)
• Stereo/Mono switch As required (internal - zone 1 only, default:stereo
)
• Expand Source As required (Zone/Program/Page)
• Limiter reshold +20 dBu
System Connections:
• Connect Page Microphones or Line Level paging source
• Connect Program Sources
• Connect Outputs to Amps
• Connect Remote Controls
You are now ready to calibrate the CP 64…