POWER POWER THERMAL (INACTIVE) BRIDGED +20 2 0 10 dBu 0 +20 2 0 10 dBu 0 8 READY READY 8 SOA LIMIT SOA LIMIT LEVEL +4 +10 4 6 CLIP LIMIT CLIP LIMIT 2 LEVEL +4 +10 4 6 1 BRIDGED READY SOA LIMIT CLIP LIMIT +20 2 0 10 dBu 0 8 LEVEL +4 +10 4 6 3 (INACTIVE) READY SOA LIMIT CLIP LIMIT +20 2 0 10 dBu 0 8 LEVEL +4 +10 4 6 4 BRIDGED READY SOA LIMIT CLIP LIMIT +20 2 0 10 dBu 0 8 LEVEL +4 +10 4 6 5 (INACTIVE) READY SOA LIMIT CLIP LIMIT +20 2 0 10 dBu 0 8 LEV
IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
OPERATORS MANUAL MA 6S MULTICHANNEL AMPLIFIER 1 2 3 4 5 6 CLIP LIMIT CLIP LIMIT CLIP LIMIT CLIP LIMIT CLIP LIMIT CLIP LIMIT SOA LIMIT SOA LIMIT SOA LIMIT SOA LIMIT SOA LIMIT SOA LIMIT READY READY READY READY READY READY MA 6S POWER THERMAL POWER MULTI CHANNEL AMPLIFIER BRIDGED (INACTIVE) BRIDGED (INACTIVE) BRIDGED (INACTIVE) LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 +20 8 2 0 10 dBu 0 +20 8 2 0 10 dB
FRONT PANEL DESCRIPTION 1 2 3 4 5 6 CLIP LIMIT CLIP LIMIT CLIP LIMIT CLIP LIMIT CLIP LIMIT CLIP LIMIT SOA LIMIT SOA LIMIT SOA LIMIT SOA LIMIT SOA LIMIT SOA LIMIT READY READY READY READY READY READY MA 6S POWER THERMAL POWER BRIDGED (INACTIVE) BRIDGED (INACTIVE) BRIDGED (INACTIVE) LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 LEVEL +4 +10 4 6 +20 8 2 0 1 2 3 MULTI CHANNEL AMPLIFIER 4 +20 10 dBu 0 8 2 0 5 10 dBu 0 6
REAR PANEL DESCRIPTION MA 6S WARNING CAUTION MADE IN U.S.A. RANE CORP. TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE FUSE. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE. ATTENTION AVIS UTILISER UN FUSIBLE DE RECHNAGE DE MÊME. DÉBRANCHER AVANT DE REMPLACER LE FUSIBLE.
MA 6S CONNECTIONS Direct, Biamp, and Bridged Wiring 4 OHM MINIMUM 4 OHM MINIMUM 4 OHM MINIMUM 4 OHM MINIMUM DIRECT MA 6S WARNING BIAMPED CAUTION MADE IN U.S.A. RANE CORP. TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE FUSE. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE.
Stereo Biamped Wiring TWEETER TWEETER 8 OHM WOOFER 8 OHM WOOFER MA 6S WARNING CAUTION MADE IN U.S.A. RANE CORP. TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE FUSE. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE.
OPERATION Voltage Controlled Attenuators The voltage controlled attenuators (VCAs) in the MA 6S allow a significant increase in usable volume levels without excessive clipping or interference from conventional distortion causing muting circuits. The VCAs do not affect dynamic response, distortion or noise levels of any material within the rated output specifications of the amplifier. They simply monitor the difference between Input and Output signals, and the power dissipated in the output devices.