Installation guide

7
CP52S Rear Panel
1 PAGING INPUT Euroblock connector may be wired per instructions in"CP52S Connections" on page 8.
2 MIC PHANTOM POWER switch, when ON, enables +15 volt Phantom Power to the PAGING INPUT connector. If the front
panel LINE switch is selected, Phantom Power is defeated.
3 LOW / HIGH CUT FILTER switch, when IN, limits the bandwidth of the Paging Input from 100 Hz to 7 kHz, improving
intelligibility in some installations. e Paging detector is always bandlimited to 100 Hz to 7 kHz.
4 PAGE LEVEL TRACKS ZONE LEVEL switch, when ON, forces the Paging level to track the Zone level. When OFF, Paging
level and Zone level are independent.
5 Four PROGRAM INPUTS are provided. ree are non-priority Inputs — the fourth is a Program PRIORITY Input. When
signal is detected at this Input, it is automatically selected as the Program Input source regardless of the front panel PROGRAM
SELECT setting.
6 PRIORITY DETECT THRESHOLD control allows adjusting the threshold from -∞ (signal on) to -35 dBu (typ). e factory
setting is -50 dBu.
7 PRIORITY OFF/ON switch allows disabling the automatic priority override function when in the OFF position.
8 PRIORITY RELEASE TIME control sets the delay time from last detected signal to release of automatic priority override. e
range of control is 5 seconds (ccw) to 20 seconds (cw).
9 EXPAND LEVEL trim adjusts the signal level delivered to the ZONE EXPAND OUTPUT.
0 EXPAND SOURCE switch assigns PAGE-only, PROGRAM-only or full ZONE (both) as the source for the Expand Output.
q EXPAND OUTPUT features a balanced line driver with a Euroblock connector. is mono Output may be wired balanced or
unbalanced per the instructions in "CP52S Connections" on page 8.
w ZONE MONO switch, when pressed in, sums the left and right signals to provide a mono Zone signal available at both Left and
Right Outputs.
e ZONE OUTPUT Port features a balanced line driver with a Euroblock connector. ese Left and Right Outputs may be wired
balanced or unbalanced per the instructions in"CP52S Connections" on page 8.
r ZONE REMOTE Port provides the wiring interface for the optional ZR1 wired remote. e ZR1 remote provides remote con-
trol of Zone Level and Zone Program Select functions. See "ZR1 Remote" on page 8.
t Universal Voltage Input: via a miniature IEC 60320 C6 appliance inlet. is mates with an IEC 60320 C5 line cord (USA
domestic). Do not lift the ground connection!
PRIORITY
3
2
1
+
+
+
+
+
+
+
+
D1
D0
D1
D0
Vr
Vc
Vr
Vc
DETECT
THRESHOLD
RELEASE
SEC
PAGING INPUT
R
L
R
L
5
20
ZONE REMOTE
ZONE OUTPUT
MIN
MAX
PROGRAM
INPUTS
RIGHT
LEFT
MONO
EXPAND
LEVEL
PROGRAM
LEVEL
OFF
ON
100-240 V
50/60 Hz 12 WATTS
ZONE
PAGE
SOURCE
PROGRAM
INPUT
LOW / HIGH
CUT
FILTER
PAGE LEVEL
TRACKS
ZONE LEVEL
MIC
PHANTOM
POWER
IN
OUT
OFF
ON
OFF
ON
100 Hz / 7 kHz
+15V
EXPAND OUTPUT
COMMERCIAL AUDIO
EQUIPMENT 24TJ
R
ALL AUDIO AND REMOTES ARE CLASS 2 WIRINGMADE IN U.S.A. RANE CORP.
CP52S
15 14 13 11 10
8 7 6 4 3 2 15
12
9