Installation manual
MONGOOSE
Installation Manual
46
Color / Text Meaning Recommended Action
Mongoose
Port Power
Failure
The Mongoose has detected
that the power level on one or
more ports is below the allowed
threshold for ‘good power’.
Check the status on the individual RADs to determine which Mongoose
ports are experiencing a power failure.
See the previous table on RAD Status for suggestions on troubleshooting
individual Mongoose port power failures.
RAD Power
Error
One or more RADs are reporting
that their power level is below
the allowed threshold of ‘good
power’
Check the status on the individual RADs to determine which have a power
error.
See the previous section on RAD Status for suggestions on troubleshooting
individual RAD power errors.
RAD Audio
Rx Error
One or more RADs are reporting
that they do not sense an Audio
lock from the Mongoose.
Check the status on the individual RADs to determine which have an Audio
Rx error.
See the previous section on RAD Status for suggestions on troubleshooting
individual RAD Audio Rx errors.
RAD Audio
Tx Error
The Mongoose does not sense
an Audio lock from one or more
RADs.
Check the status on the individual RADs to determine which have an Audio
Tx error.
See the previous section on RAD Status for suggestions on troubleshooting
individual RAD Audio Tx errors.
Hardware Error
An unknown internal error
has occurred in the Mongoose
device.
Power cycling the Mongoose and restarting the Mongoose Tracker may
resolve this issue.