FADER CLEANING
With heavy use in harsh environments, the fader
may need lubrication. This treatment extends
longevity and can make a used fader as good as
new. The fader assembly must be removed from
the MP 4 for proper cleaning. We recommend
any of the following cleaning solutions:
Caig DeoxIT FaderLube F100 spray
lubricant
Caig DeoxIT FaderLube F5 spray cleaner
CRC 2-26 (www.crcindustries.com)
Order CaiLube MCL® from:
CAIG Laboratories, Inc.
12200 Thatcher Ct.
Poway, CA 92064
Phone: 858-486-8388
Fax: 858-486-8398
Web: www.caig.com
CLEANING INSTRUCTIONS
A. Fader assembly replacement (part #11646)
1. Unplug the MP 4.
2. Remove the bottom cover.
3. Remove the fader screws from the front panel.
4. Draw fader assembly out through the bottom.
5. Remove ribbon cable from old fader.
6. Attach ribbon cable to new fader.
7. Screw onto front panel
8. Replace bottom cover.
B. Fader cleaning
1. Hold the fader assembly away from the mixer.
2. Position the fader at mid-travel.
3. Spray cleaner/lubricant into both ends of the fader in sufficient amounts to flush debris.
4. Move the fader over its full travel back and forth a few times.
5. Shake excess uid from the fader assembly.
6. Wipe off excess uid.