RTA 0 dB METER 25 31.5 -30 40 50 -27 63 -25 80 -24 -18 -20 -15 -12 -15 -9 100 125 160 200 250 315 400 500 630 800 -21 1k 1.25k 1.6k -6 2k -3 -10 2.5k 3.15k 4k 5k +3 6.3k -5 8k +6 +12 0 10k 12.
IMPORTANT SAFETY INSTRUCTIONS For the continued safety of yourself and others we recommend that you read the following safety and installation instructions. Keep this document in a safe location for future reference. Please heed all warnings and follow all instructions. Do not use this equipment in a location where it might become wet. Clean only with a damp cloth. This equipment may be installed in an industry standard equipment rack.
OPERATORS MANUAL RA 30 REALTIME ANALYZER -30 METER -27 -25 -24 -21 -18 -20 -15 -12 -15 -9 -6 -3 -10 +3 -5 +6 +9 +12 0 3 0 dB RTA 25 31.5 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1k 1.25k 1.6k 2k 2.5k 3.15k 4k 5k 6.3k 8k 10k 12.
Front Panel Description 0 dB VU METER MODE -30 METER -27 -25 -24 -21 -18 -20 -15 -12 -15 -9 -6 -3 -10 +3 0 dB SPL METER MODE -5 +6 +9 +12 0 3 0 dB 6 dB RTA 25 31.5 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1k 1.25k 1.6k 2k 2.5k 3.15k 4k 5k 6.3k 8k 10k 12.
Rear Panel Description PINK NOISE OUTPUT POWER LINE IN RA 30 AUX MIC PIN 2 POSITIVE PIN 3 NEGATIVE PIN 1 CHASSIS GROUND OL 600mA CLASS 2 EQUIPMENT LEVEL RIGHT UNBAL LEFT/MONO GAIN BAL/UNBAL MADE IN U.S.A. RANE CORP. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Step by Step Instructions I. Stereo VU Meter A. Connect program source to the LINE INPUTS on the rear. If mono operation is desired, connect the mono program source to the LEFT INPUT. B. Set the SOURCE switch to LINE IN. C. Set the GAIN control to the center detent to calibrate the 0 dB mark on the VU scale to +4 dBu. OR Set the GAIN control fully clockwise to calibrate the 0 dB mark on the VU scale to -10 dBV. D. Select the METER mode by pressing the METER/RTA button so the METER LED illuminates. E.
Alignment Instructions Since the RA 30 features a unique form of realtime analyzer, we highly recommend that you read this section before performing an alignment with pink noise. If you’ve never used an analyzer before, use these instructions on your first occasion. You’ll be delighted at how simple it really is. WEIGHTING FILTERS Used in SPL mode, the filter “weights” or gives more attention to certain frequency bands than others.
Noise test settings the same amount at each performance; make a note of these further adjustments to save future tweaking during performances. For example, you note the pink noise settings and find later that you like to have 3 dB more boost at 63 Hz for more low-end punch during the performance.