User's Manual

TF 407 & TF 410
MA 3 TRANSFORMER KITS
Description
Up to three optional 70.7 V or 100 V constant-voltage distribution transformers may be
mounted inside the MA 3 with no external wiring or mounting required.
• e TF 407 is a 40W, 70.7 V transformer with 0.5 dB insertion loss at rated power and a frequen
-
cy response of 50 Hz to 15 kHz, ±1 dB.
• e TF 410 is a 40W, 100 V transformer with 0.5 dB insertion loss at rated power and a frequen
-
cy response of 50 Hz to 15 kHz, ±1 dB.
Installation WARNING — Only authorized service personell should perform this upgrade.
1. Unplug the MA 3 amplifier!
2. Remove the top cover (12 screws).
3. Capacitors C63, C61, C62 and C65 need to be laid toward the rear of the unit (Figure 1). Dont
press on parts, just gently lay them over.
4. Stand the MA 3 up on one end with the power transformer toward the bench (Figure 2).
5. Locate the transformer mounting holes along the rear panel of the MA 3 (Figure 2).
6. Place one of the two supplied #8 screws in the “top” mounting hole of the pair of holes associated
with the channel receiving the transformer (Figure 2).
e “bottom” two holes are for Channel 3.
e “center” two holes are for Channel 2.
e “top” two holes are for Channel 1.
7. With the transformer primary (WHT & BLK) wires facing the PCB, “hang” the transformer on
the #8 screw and nylock nut. Hold the screw and transformer in place with one hand. Use your
other hand to rotate the supplied #8 nut onto the threads. Use a nut driver and #2 Phillips driver
to snug the hardware. Install the second #8 screw and nylock nut. Make sure hardware is tight.
8. Repeat for additional Channels if more than one transformer is required. When installing more
than one, start at the bottom (Channel 3).
Figure 2. Transformer mounting
holes for each channel.
INSTALLATION MANUAL
Gently lay capacitors back toward the rear
Ch 1 Ch 2 Ch 3
360 WATTS
120V
50/60 Hz
N108
OUTPUT POWER
PER CHANNEL
40 WATTS / 8 OHMS
60 WATTS / 4 OHMS
MAY USE CLASS 2 WIRING
LEVEL
+
-
+
-
++++
----
+++
---
+
-
+
-
+
-
NORMAL
FAST
100
LEVELLEVEL
100100
FOR
CONTINUED
GROUNDING
PROTECTION
DO NOT
REMOVE SCREW
MA 3
MADE IN U.S.A.
RANE CORP.
AVIS
RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRICAL
SHOCK DO NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE. DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED PERSONNEL.
CH 3 CH 2 CH 1
OUTPUTS INPUTS
CHANNEL
1CHANNEL 2CHANNEL 3 FAN SPEED
3
2
1
Figure 1. Capacitor clearance

Summary of content (2 pages)