Fader Calibration
After cleaning or replacement, the sensors may get moved, affecting the contour. After any fader service,
perform this procedure to re-calibrate the faders and crossfader.
1. Power off the Sixty-Two.
2. Move all faders to the center-most position.
3. Push down both DECK 1 CUE and DECK 2 CUE buttons at the same time.
4. While holding these buttons down, power on the Sixty-Two.
5. Immediately after powering up, the CUE lights will ash one time, indicating a successful calibration.
If the CUE lights ash three times, the sensors may have moved too far or all faders were not properly
centered, and the faders cannot correctly calibrate.