User's Guide
INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
16
L
N
Live: brown Neutral: blue
Earth: yellow & green
Earth: to the
terminal marked E,
coloured Green/Yellow
Live: to the
terminal marked L,
coloured Brown
Neutral: to the
terminal marked N,
coloured Blue
All dimensions in millimetres
800
600
A
400
300
Gas inlet block
Fig. 6.3
Fig. 6.4
Fig. 6.5
Gas Connection
This must be in accordance with the relevant standards.
The exible hose (not supplied with the cooker) must be
in accordance with the relevant standards. Hoses may be
purchased at most builders’ merchants.
The gas supply needs to terminate with a down-facing
bayonet.
The connector is located just below the hotplate level at the
rear of the cooker. If in doubt contact your supplier.
Because the height of the cooker can be adjusted and
each connection is dierent, it is dicult to give precise
dimensions.
The maximum length of the hose should not exceed 1500mm
The hose should be tted so that both inlet and outlet
connections are vertical so that the hose hangs downwards in
a ‘U’ shape.
Ideally the hose supply connection should be within the
shaded area ‘A’ (Fig. 6.3).
For Natural Gas, the exible hose must be in accordance with
BS 669. For LP Gas, it should be capable of 50 mbar pressure
and 90 °C temperature rise. If in doubt contact, your supplier.
After completing the gas connection, make sure that the
cooker is gas sound with soapy water or leakage uids.
Electrical Connection
All external wiring must comply with the IEE Regulations
for the Electrical Equipment of Buildings. Connection to the
electrical supply is via a plug and socket.
Do not use an extension lead.
n
WARNING: THIS APPLIANCE MUST BE EARTHED.
Three pin plugs to BS 1363 with a capacity of not less than
13 A must be used and tted with a 13 amp fuse ‘ASTA’
approved to BS 1362.
You must ret the cover after replacing the fuse. If the cover is
lost, the plug must not be used until a replacement cover has
been obtained from your supplier. The colour of the correct
fuse carrier is that of the coloured insert in the base of the
fuse recess, or stated elsewhere on the plug. Always state this
colour when ordering a replacement fuse carrier.
IMPORTANT: The wires in the mains lead are coloured in
accordance with the following code (Fig. 6.4 and Fig. 6.5):
• Green and yellow: EARTH
• Blue: NEUTRAL
• Brown: LIVE