Owner's manual
Table Of Contents
- Chapter 1: Introduction
- Chapter 2: Accessing CC-SG
- Chapter 3: Configuring CC-SG with Guided Setup
- Chapter 4: Creating Associations
- Chapter 5: Adding Devices and Device Groups
- Chapter 6: Configuring Nodes and Interfaces
- Chapter 7: Adding and Managing Users and User Groups
- Chapter 8: Policies
- Chapter 9: Configuring Remote Authentication
- Chapter 10: Generating Reports
- Audit Trail Report
- Error Log Report
- Access Report
- Availability Report
- Active Users Report
- Locked Out Users Report
- User Data Report
- Users in Groups Report
- Group Data Report
- AD User Group Report
- Asset Management Report
- Node Asset Report
- Active Nodes Report
- Node Creation Report
- Query Port Report
- Active Ports Report
- Scheduled Reports
- CC-NOC Synchronization Report
- Chapter 11: System Maintenance
- Chapter 12: Advanced Administration
- Appendix A: Specifications (G1, V1, and E1)
- Appendix B: CC-SG and Network Configuration
- Appendix C: User Group Privileges
- Appendix D: SNMP Traps
- Appendix E: Troubleshooting
- Appendix F: Two-Factor Authentication
- Appendix G: FAQs
- Appendix H: Keyboard Shortcuts

50 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE
Device Power Manager
Device Power Manager is used to view the status of a PowerStrip device (including voltage,
current, and temperature) as well as manage all power outlets on a PowerStrip device. As
opposed to powering Nodes on and off individually, Device Power Manager provides a
PowerStrip-centric view of its outlets.
Before using the Device Power Manager, a physical connection needs to be made between a
PowerStrip and a Dominion SX or Dominion KSX unit. When you add the PowerStrip device,
you must define which Raritan device is providing the connection. This will associate it with the
Dominion SX serial port or with Dominion KSX dedicated power port that is providing
management of the PowerStrip.
1. In the Devices tree, select a PowerStrip device.
2. On the Devices menu, click Device Power Manager. The Device Power Manager screen
appears.
3. The outlets are listed in the Outlets Status panel. You may have to scroll to view all outlets.
4. Click the On or Off radio buttons for each outlet to power ON or power OFF the outlet.
5. Click Recycle to restart the device connected to the outlet.
6. Click Close to close the Device Power Manager screen.
Launch Admin
If available, the Launch Admin command will provide you access to the administrator interface
of the selected device.
1. Click the Devices tab and select the device whose administrator interface you want to launch.
2. On the Devices menu, click Device Manager, and then click Launch Admin. The
administrator interface for the selected device will appear.
Figure 48 Launch Admin for a KX Device