- Raritan Paragon II User Guide

CHAPTER 2: INSTALLATION 23
Installing a HubPac
Please use the Basic Installation instructions below to create 32-user Paragon Matrix Switching
configuration.
UserStation
(1-8)
1IN
1-1 1-2 1-3 1-4
UserStation UserStation UserStation UserStation UserStation UserStation UserStation
ENT
FUNC
ESC
ENT
FUNC
ESC
ENT
FUNC
ESC
ENT
FUNC
ESC
(1-8) (1-8)
(1-8)
(Users 1-8) (Users 9-16) (Users 17-24) (Users 25-32)
Up to 32 Users Per Server
Back of HubPac
5IN
5-1 5-2 5-3 5-4
6IN
6-1 6-2 6-3 6-4
7IN
7-1 7-2 7-3 7-4
8IN
8-1 8-2 8-3 8-4
1IN
1-1 1-2 1-3 1-4
2IN
2-1 2-2 2-3 2-4
3IN
3-1 3-2 3-3 3-4
4IN
4-1 4-2 4-3 4-4
AC Power
115V/230V
60Hz/50Hz
AC IN
0.6A/0.3A
On Off
Server
UKVMP
Cat 5e Cable
UMT832
USTI
Cat 5e Cable
Cat 5e Cable
Figure 28 Connecting a P2-UMT832M to a HubPac
1. Power OFF each Paragon switch
Note: Prior to installation all Paragon switch units and HubPac units must be powered OFF.
Computers and User Stations (UST1s) to be connected can be in a powered ON state.
2. Connect one HubPac to four Paragon Matrix Switch model UMT8 units, creating an 32 user
by 8 server configuration:
A. Attach server(s), via CIM, to HubPac:
Note: Up to 8 servers can be connected to one HubPac. Each 5-port cluster on the HubPac
represents one server connection, with four associated HubPac user ports. When each HubPac
user port in a cluster is attached to a separate Paragon switch, 32 users (4 HubPac user ports x 8
users per Paragon switch) can have access to each server.
B. Connect CIM to server – see Appendix A: Specifications for specific instructions on
connecting different CIM types to a server.
C. Connect one end of a Category 5e UTP cable to RJ45 port on CIM.
D. Connect the other end of cable to the RJ45 1-IN port on back of HubPac.
E. Power ON server.
F. Repeat above steps to connect the remaining servers, connecting the Category 5e UTP
cable to the HubPac at the RJ45 2-IN, 3-IN, 4-IN, 5-IN, 6-IN, 7-IN, and 8-IN port for
each consecutive server (2 through 8) added.
3. Connect HubPac to each Paragon Matrix Switch by repeating all of the following steps for
each 5-port cluster on HubPac:
A. Connect one end of a Category 5e UTP cable to the RJ45 X-1 port on back of HubPac.
B. Connect the other end of the cable to channel port # N on the back of Paragon Matrix
Switch number 1.
C. Connect one end of a Category 5e UTP cable to the RJ45 X-2 port on back of HubPac.