User guide

Chapter 14: Frequently Asked Questions
Questions
Answers
How do I enable Direct
Port Access with a
Dominion SX unit running
SX3.1+ firmware?
Enabling Direct Port Access (DPA) from the CLI in Dominion SX.
Attached is a sample run for DPA configuration from CLI.
The following are main steps:
1. Configure DPA mode from Configuration->Services.
2. Configure which port need DPA and type of DPA (Telnet-TCP, SSH-
TCP, IP ADDR) from Configuration->ports
3. Reboot SX
4. Reapply Configuration-Services settings, for SSH, Telnet to take effect
of DPA settings.
5. Reboot SX
DPA should be functional on 2
nd
reboot
What are the pin-outs of
the Dominion SX RJ45
serial ports?
Dominion SX Serial Pin-outs
The RJ45 connector on the rear of the unit has the following pinout:
RJ45 PIN
SIGNAL
1
RTS
2
DTR
3
TxD
4
GND
5
Signal GND
6
RxD
7
DSR
8
CTS
How do I install Java?
See the Standalone Raritan Serial Console section of Chapter 5: Port
Configuration and Port Access Application of the Dominion SX User Guide.
Is the status of the unit
limited by the status of
the device or equipment
to which it is attached
(that is, Server, router,
firewall, load balancer, or
other network device)?
No, because the unit is a totally "out of band" solution that runs on its own
dedicated microprocessor.
Even if the target devices to which the Dominion SX is attached are turned
off, you will still be able to access the unit.
Can I reset the unit
without losing my
settings?
Click Maintenance > Reboot to reset the system.