User's Manual

Company Confidential 24 Raveon Technologies
SV
Save Save all the parameters to EEPROM. This command
must be used if changed parameters are to be stored in non-
volatile memory, and used next time the modem is powered
up. Modem exits configuration mode after this command is
executed. It saves all parameters except the frequency (The
frequency is automatically saved when an ATFT, ATFR, or
ATFX command is executed)
none
None
TD
Transmit Random Data When issued, the modem will begin
sending random data. Entering a <CR> will terminate the
transmission.
0 = Go back to normal
1 = Random
2 = Hop up/dn one channel
3 = 1010… at ¼ baud rate
4 = TX all 0s
5 = TX all 1s
6 = Test Points ON
7 = Transmit CW
8 = Transmit 1010101…
TE
Read product temperature Read the internal temperature
of the unit’s circuit board.
1 - 512
200
TT
Max Packet Size Set the maximum number of bytes in an
over-the-air packet.
1 - 512
200
VB
Read DC input Voltage Returns the DC input voltage
reading, in mV (12500 = 12.5VDC input).
None
none
VR
Firmware Version Returns firmware version currently
loaded on the module.
Read Only, 3
characters
none
Xn
Show or Configure the Repeat Table Set the addresses
that this unit will store-and-forward data to/from. n = 1, 2, 3, or
4 designating the entry in the table to show or edit..
Four parameters
aaaa bbbb cccc dddd where
aaaa=Source Address
bbbb = S.A. Mask
cccc = Destination Address
dddd = D.A. Mask
XR
Enable/Disable Store and Forward Repeating 0=disabled,
1 enabled.
0 or 1
0 (Off)
XT
Read/set repeater delay Read or set the repeater delay.
This is the time between receiving a data packet, and the time
the repeater will re-send it.
&F
Restore Factory Restore the factory default values. This
command will not erase the calibration values. After this
command executes, the modem will still be in the CONFIG
mode.
none
** indicates values that are calibrated in the factory and are unit-specific. If the “Radio
Type” is changed, these will need to be re-calibrated.
5.8 Other non-AT commands
SHOW
Show/display an overview of the radio’s configuration.
None
none
PING
Ping another modem. Format is PING xxxx, where xxxx is
the ID of the modem to ping. If remote access is enabled on
xxxx, it will respond.
RPR
Remote Procedure Request. Used to request execution of a
command on a remote mode (over the air). See M7-UC
System Protocol manual for information on using this feature.