User's Manual

Company Confidential 52 Raveon Technologies
M7-UC-W (wide-band version)
For high-speed operation, set R2 to 5 (9600 baud).
For best range (longest distance), set R2 to 1 (1200 baud)
Other data rates of 0(800bps), 2(2400bps), 3(4800bps), 7(9600bps), and
6(19,200bps) will work, but have a less optimal bit-error-rate vs. receive
sensitivity.
10.2 Debug Related Commands
Bench Testing
(Must be in command mode to test. Enter +++ at the keyboard to put unit into config/test mode.)
ATTD x Various transmit test routines.
0 = Go back to normal mode. Stops the test.
1 = Random data transmit.
2 = Hop up/down one channel
3 = Force PLL to fast lock mode
4 = Transmit all 0s
5 = Transmit all 1s
6 = Enable the test points on the PCB.
7 = Transmit CW on center of channel
8 = Transmit preamble (101010 pattern)
SHOW Display an overview of the configuration.
Ping xxxx Ping another modem over the air. Transmits a request to xxxx to see if
xxxx can hear the sending station. If it does, it answers with a response
transmission, containing its ID and the signal strength of the reception. .
ATST Display statistics of how the modem is working.
ATST 1 Display statistics of how the modem’s GPS is working (if installed).
AT$5 Display RSSI. It will scroll the reading until another character comes in
the serial port.
Packet Counter
The packet counter mode will output packet count statistics once per minute. It
will output the number of packets received in the last minute as well as the
running total. T
ATPE Begin counting and displaying the packet counters every minute
ATPE 1 Reset the packet counters back to zero
ATPE 2 Stop counting and displaying packet counters