User's Manual

Company Confidential 14 Raveon Technologies Corp.
1. Serial port 9600 baud, 8 data bits 1 stop, no parity
2. ATCT setting set to 60000 (60 second time-out)
3. Serial port on the front of the unit in RS232 mode, 9600bps, N/8/1.
Even though the serial baud rate reverts to 9600 baud when the CONFIG
button is pressed and the IO port is RS232, it will revert back to the settings
programmed into the M8S modem once the Command Mode is exited.
5.6. Exiting the Command Mode
There are three ways to exit the command mode. They are:
1. ATCN Issuing the ATCN. The M8S radio will exit the command mode,
and begin normal operation.
2. EXIT Issuing the EXIT. The M8S radio will exit the command mode, and
begin normal operation.
3. Time Out. After a pre-set amount of time (60 seconds is the factory
default time), the modem will automatically exit the Command Mode, and
continue normal operation. Changes will not automatically be saved. This
time-out duration may be set with the ATCT command.