User's Manual

Company Confidential 28 Raveon Technologies Corp.
6.8. Command Mode Commands
AT
Command
Command Description Parameters
Factory
Default
AK
Enable/Disable ARQ When ARQ is enabled, this modem
will automatically send an ACK packet back to a modem that
sends it data. 0=off, 1=on.
Range: 0 1
0 (no AKCs
sent)
AS
Auto Status Report Interval Sets the time between auto
status reports. Time is in minutes. 0 means disabled.
Range: 0 –56000
(minutes)
0 (Off)
AT
Silence AFTER Sequence - Sets period of silence after the
command sequence characters in mS.
Range:0 1000
(mS)
500
BD
Baud Rate Sets serial com port baud rate (bps). Over-the-
air (throughput) baud rate is set with ATR2 command.
If a PC’s serial baud rate is set higher than the fixed over-the-
air baud rate of the module, hardware handshaking may be
required.
Range: 0 6
0 = 1200 bps
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
3
BC
Busy Channel Lock Out Enable/disable the BCL. When
enabled, the modem will not transmit on a radio channel that
is busy (has RF on if). 0-OFF, 1=ON. This feature must
remain enabled.
Range: 0-1
1
BT
Silence BEFORE Sequence Sets period of silence before
the command sequence character in mS.
Range: 0-1000
mS
500
CH
Configure Hardware Flow Control Enable (1) or disable
(0) flow control. When enabled, the modem will monitor the
RTS line, and if it is negated, stop sending data out the serial
port. If disabled, the modem will ignore the state of RTS, and
always send out charators.
1 = Enable
0 = Disable
0
CN or O
Exit AT Command Mode Exits module from AT Command
Mode and returns it to Idle Mode. Parameters are not saved
in EEPROM.
none
none
CT
Time Out from AT Command Mode If no valid commands
have been received within this time period (in milliseconds),
modem returns to normal operation mode from Command
mode. If the CONFIG button inside the FireLine is pressed,
this parameter will be automatically set to 60000.
Range: 100-60000mS
60000
DT
Destination Address to call Sets address of the modem to
send data to. Note, this parameter is entered in HEX format.
Each digit may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or an F.
Range: 0-FFFF 1234
E0 , E1
Echo Character echo set on (E1) or off (E0). This applies to
the Command Mode only.
Range: 0 , 1 0 (no echo)
HP
Channel Number Select separate channels to minimize
interference between multiple sets of modules operating in the
same vicinity.
Range: 1 - 6
1
L
Enable/Disable the LEDs 0 = LEDs always off. This
reduces some power consumption. 1 = LED operate normally.
0 or 1
1
MA
Monitor Address
Configures the address to which status
transmissions are sent to. Only used if Auto Status is enabled.
Each digit may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or F. Note:
FF is interpreted as a group. See addressing section.
Range: 0000 - FFFF
FFFF