User's Manual

mn100 Digital Display
20
(s15) WAYPNT ARRIVAL
Sets the instrument to alarm if a Waypoint Arrival Alarm is
issued by the GPS. On/Off.
3.5 Calibration Page Description
In each case press the button quickly to edit, press the
or to change units and press the button quickly to select
the chosen units. Default values are indicated in bold.
Speed Chapter
(s16) RESP Spd
Sets the update period of the Speed display.
Auto/Slow/Medium/Fast
(s17) SPEED
The Boat Speed Calibration Factor adds a percentage
factor which corrects the information from the
paddlewheel and ensures the boat speed is displayed
correctly. See page 25 for calibration.
(s18) SPEED FORMAT
Sets the number of decimal places to which the Boat
Speed information is displayed. Applies to the units
selected on page 18 -s6. Options are 0.1 or 0.01.
(s19) SEA
The Sea Temperature Calibration Factor Adds a
percentage factor which corrects the information from the
temperature sensor and ensures the water temperature is
displayed correctly.
Depth Chapter
(s20) KEEL
Allows a Keel Offset to be added allowing the instrument
depth reading to indicate depth below the bottom of the
boat, or a Waterline Offset allowing the depth reading to
indicate actual water depth. See page 24 for calibration.
Setup and Calibration
17
Editing Values
To adjust any settings press the button. The setting will start
to flash and the
and buttons will change the value.