Installation Instructions Part 1

35 Chapter 4: Cables and connections
Circuit protection
GPM400 processor
All GPM400 processors must be switched via a single breaker.
General circuit protection
The following loads and protection ratings apply to G-Series dis-
plays and ancillary equipment:
Power cables
Cable must be of a suitable gauge for the circuit load.
Each unit should have its own dedicated power cable wired
back to the distribution panel.
All GPM400 processors should be connected to the same
breaker.
Power cable must include a separate screen wire.
Number
of
GPM400
units
Supply
voltage
Thermal
breaker
(Overall)
Fuse
(Individual)
1 12 V 10 A 10 A
24 V 5 A 5 A
2 12 V 20 A 10 A
24 V 10 A 5 A
3 12 V 25 A 10 A
24 V 15 A 5 A
4 12 V 35 A 10 A
24 V 20 A 5 A
Equipment
Supply
voltage
Thermal
breaker
Fuse
G190 marine display 12 V 8 A 12 A
24 V 4 A 6 A
G170 marine display 12 V 8 A 12 A
24 V 4 A 6 A
GVM400 Video Module 12 V 1.2 A 2 A
24 V 1 A 1 A
For other ancillary equipment, refer to the separate installation instructions for
circuit loading and protection information.
Equipment
Supply
voltage
Thermal
breaker
Fuse