User's Manual

3
Installation Preparation
rage
y.
ower
ious
the
ratic
nside
s
bolts
2. Determine the Cable Requirements
Depending on your Humminbird model and network configuration, you may need to purchase additional
accessories to connect your Radar scanner to your control head or Ethernet network. Before starting the
installation, determine whether you will need to purchase Ethernet Adapter Cables or extension cables.
Also, see Connect to Power and Ethernet for more information.
NOTE: To purchase Ethernet Accessory Cables, extension cables, or the Ethernet Switch, visit our Web site
at humminbird.com or call Humminbird Customer Service at 1-800-633-1468.
3. Create a Schematic Diagram
A schematic diagram is an essential part of planning any installation. It is also useful for any future additions
or maintenance of the system. The diagram should include the following:
Location of all components
Cable types, routes, and lengths.
NOTE: Confirm that you have read and understood the warnings and cautions provided in the Important
Information section before proceeding with the installation.
Hardware Cable Requirement to Connect to Radar Scanner Voltage Requirements
ONIX No additional cables required. 12 VDC
HELIX
Separate purchase AS EC QDE Ethernet Adapter
Cable is required.
12 VDC
Ethernet Switch No additional cables required. 12 or 24 VDC
Example of a Schematic Diagram with a Direct Connection to the Control Head
Radar scanner
control head power cable
(6 ft [2 m])
Radar scanner
power cable
(32.8 ft [10 m])
control head
power supply
AS EC M12 to RM data cable (included)
(32.8 ft [10 m])
ONIX control head
separate 12/24 V
power supply
CHIRP_Radar_Install_Manual_532523-1EN_A.qxp_Layout 1 8/11/16 10:48 AM Page 3