Scanner PackageScanner Package
Scanner PackageScanner Package
Scanner Package
Inter-Unit CableInter-Unit Cable
Inter-Unit CableInter-Unit Cable
Inter-Unit Cable
2D (US) 10m light (2 power cores)
2DE (European) 15m light (2 power cores)
4D 15m heavy (4 power cores)
The minimum bends permitted are:
Minimum bend, light cable 60 mm (~2.5 in) radius
Minimum bend, heavy cable 82 mm (~3.75 in) radius
The length of the supplied cable should be sufficient to complete the cable run
required on most small vessels. For longer runs, additional or replacement
cables are available, which have 4 power cores to minimise voltage drops over
the longer cable run: these optional cables include 5m and 10m extension
cables, and a 25m replacement cable.
The maximum inter-unit cable length is limited by the minimum supply
voltage, the scanner type (18" radome or 24" radome), and the cable type (2 or 4
power cores): if a mix of light and heavy cables is used, only 2 power cores are
connected through.
Note: For vessels with 24V power systems, any combination of inter-unit
cables can be used.
For vessels with 12V power systems, the recommended cable(s) for different
run lengths are given in the following table, which assumes a minimum supply
voltage of 10.7V (the lowest voltage likely to be reached by a 12V battery in
normal marine use). Do not use cable combinations that are not included in
the table.
Recommended Radome Inter-Unit Cable(s) for Vessels with 12V Power
Systems
Inter-Unit Cable Scanner Package
Length Required (m) 2D (US) 2DE (Eur) 4D
10 Std 10m light N/A N/A
15 Std + 5m ext Std 15m light Std 15m heavy
20 Std + 10m ext 25m assembly Std + 5m ext
25 25m assembly 25m assembly Std + 10m ext
30 25m + 5m ext 25m + 5m ext 25m + 5m ext
35 25m + 10m ext 25m + 10m ext 25m + 10m ext
Refer to the packing list in Section 1.2 for cable part numbers