Owner's Handbook

Table Of Contents
28 Pathfinder Radar Scanners
Connecting the open array scanner inter-unit cable
CAUTION:
Before wiring the scanner unit check that it is securely mounted
to the platform, then make sure that the inter-unit cable is not
connected and power is not applied to the display unit. The
scanner switch must be in the OFF position.
1. Loosen the four self-retaining bolts securing the pedestal lid to the
base. Pull-up and turn the bolts anti-clockwise to lock them in the
upright position. Remove the lifting eyes.
Note: It is important to remove lifting eyes to avoid corrosion. Retain
the lifting eyes: they will be required if the scanner is removed from its
platform.
2. Open the pedestal lid. Ensure the securing stay has automatically
locked into position.
3. Referring to the following illustration, remove the cable gland
nut, washer and grommet from the watertight gland, where the
inter-unit cable will enter the base.
Lifting eye
32 mm
max.
D4573-4
Pedestal
IMPORTANT
Bitumen washer, MUST
be sticky side down
on mounting
platform
Mounting
platform
M10 plain washer
M10 spring washer
M10 stud
length = 52 mm
plus platform depth
M10 nut