Owner's Handbook

Table Of Contents
Chapter 2: Installing the Scanner 31
and the black cable leads to the terminal socket marked “-”, with
one lead in each socket. The terminal clamps are operated using a
screwdriver as shown in the inset diagram.
9. Using the tie-wrap fitting on the pedestal lid, secure the cable.
10. Check the seal in the pedestal lid is correctly seated.
Grease the four self-retaining case bolts and thread holes with
Denso paste (supplied).
Close the pedestal lid, ensuring that the cable does not become
trapped and that the seal is not pushed-out at the front of the ped-
estal: it will help if you support the front of the lid (by holding the
mounting bracket) as you lower the rear of the lid.
11. Tighten the four self-retaining bolts to 12 Nm (8.8 lb ft).
Tighten the cable gland nut 1/2 turn.
CAUTION:
Do not grease the seal in the pedestal lid.
Grey
Purple
Blue
Green
Yellow
Orange
Coaxial Screen
(Black)
Coaxial Inner
(White)
Signal connector
Power connector
D4576-2