Implementationconnectiontodistributionpanel
Alternatively,thesuppliedpowercablemaybeconnectedtoasuitablebreakerorswitchonthe
vessel'sdistributionpanelorfactory-fittedpowerdistributionpoint.
Thedistributionpointshouldbefedfromthevessel’sprimarypowersourceby8AWG(8.36mm
2
)
cable.
Ideally,allequipmentshouldbewiredtoindividualsuitably-ratedthermalbreakersorfuses,with
appropriatecircuitprotection.Wherethisisnotpossibleandmorethan1itemofequipmentshares
abreaker,useindividualin-linefusesforeachpowercircuittoprovidethenecessaryprotection.
1
Positive(+)bar
2
Negative(-)bar
3Circuitbreaker
4Fuse
Inallcases,observetherecommendedbreaker/fuseratingsprovidedintheproduct’s
documentation.