19.19Sounderset-upmenuoptions
ThissectiondetailstheoptionsavailableintheSounderset-upmenu:(Menu>Set-up>SounderSet-up).
MenuItemDescriptionOptions
*PingRate
HyperPingisasettingonlyavailableon
TraditionalinternalandLegacysonarmodules,for
useinshallowwaters(depthrangesetto6meters
(20feet)orless.Indepthsofover6meters(20
feet)thepingratewillreverttonormaluntildepth
conditionsaremet.
WhensettoHyperthedisplaywillprovidean
accurate,undistortedimageofthebottomat
speedsofupto40kts.
Normal(default)
Hyper
*PingRateLimitProvidesaspeedlimiter;itisusefultoadjust
thepingratelimittosuitlocalconditions.For
example,thepingratemaybetoofastwhenthere
isahardbottominshallowwater.
Note:PingratelimitisdisabledifPingRateis
settoHyper.
DownVision
TM
sonar:5to80pings
persecond.
LegacyandTraditionalInternalsonars:
5to50pingspersecond.
CHIRPandtraditionalexternalsonars:
5to30pingspersecond.
PingEnable
Thesonarpingcanbedisabled.Thisisuseful
whenotherequipmentisbeingtested,orif
someoneisdivingbeneaththeboat.Thissetting
revertstoEnabledwhenthesonarmoduleis
poweredoff.
On
Off
*TuneFrequencyEnablesnon-CHIRPchannelfrequenciestobe
manuallytuned.
–50%to+50%
*Interferencerejection
Removesspikescausedbyother
shnder-equippedvessels.
Note:Interferencerejectionisbedisabledif
RingRateissettoHyper.
Auto
Low
Medium
High
Off
*2ndEchoIR
Adjuststhepingrateinsmallincrements,
accordingtothe2ndecholevel.Thisresultsin
bettersensitivityoftheimage.
Note:2ndEchoIRisbedisabledifRingRate
issettoHyper.
Off
Low
High
SonarresetRestoreallsettingsonthesonarmoduletofactory
default.WhenperformingasonarReset,itis
normaltobrieyloseconnectionwiththesonar
module.
TransducerselectionisnotaffectedbytheSonar
Resetoperation.
Yes
No
TripReset
ResetstheTripCounterofthesonarmodule
Yes
No
Note:*NotapplicabletoSideVision