Installation guide

Maintenance and troubleshooting 31
For example, if the transducer sense fails and the network is not
detected, the LED blinks amber once, pauses 1.5 seconds,
blinks amber twice 0.5 seconds apart, pauses 1.5 seconds and
then repeats the sequence until the problems are resolved or up
to 10 minutes elapse.
3.7 Contacting Raymarine
Using the website
For the latest information on Raymarine products visit the
website at www.raymarine.com.
Click on the region that you are located in and go to the
Customer Support page for links to:
Finding the location of the nearest factory service and
authorized dealer for your area.
Register Raymarine products.
Accessing handbooks in Adobe Acrobat
TM
format.
Downloading software updates.
Accessing the Raymarine solution database.
Click Find Answers to use the searchable solution database, or
click Ask Raymarine to submit a question to Raymarine
technical support staff. A reply will be sent by e-mail.
In the US
Parts and accessories
Many Raymarine parts and accessories can be obtained from
your local authorized Raymarine dealer.
Color
No. of
blinks
Warning/error
Cleared
every 10
mins
Amber Solid DSM has rebooted No
Amber 1 Transducer sense failure No
Amber 2 Network not detected * No
Amber 3 High temperature warning Yes
Amber 4 Contact Raymarine
Amber 5 Contact Raymarine
Amber 6 Contact Raymarine
Amber 7 Contact Raymarine
Amber 8 Contact Raymarine
Red 1 Contact Raymarine Yes
Red 2 Check Voltage Supply Yes
Red 3 Contact Raymarine
Red 4 Contact Raymarine
Red 5 Contact Raymarine
* After 30 seconds of no network activity, the
sounder unit enters Standby mode; No sonar pings
are emitted and no warnings or errors are output on
the Status LED. Instead the LED will blink GREEN
once every 10 seconds.
DSM400 Installation Guide.book Page 31 Tuesday, November 4, 2008 4:53 PM