Operation Manual

4.SelectRangeRingssothatOnishighlighted.
SelectingrangeringswillswitchrangeringsbetweenOnandOff.
SafeZoneRing
ThechartapplicationcandisplayandcongureaMARPA/AIS
safezonering.
ThesafezoneringsharesitscongurationwiththeRadar
applicationssafezonering,howevercanbedisplayed
independentlyofthesafezoneringintheRadarapplication.
IfaMARPAorAIStargetwillreachthesafezoneringwithinthe
timetosafezoneselectedanalarmissounded.
EnablingSafeZones
ToshowtheSafeZoneringfollowtheinstructionsbelow:
FromthechartapplicationgotoMenu>AISOptions>SafeZone
Set-up
FromtheradarapplicationgotoMenu>TrackTargets>Safe
ZoneSet-up
1.SelectSafeZoneRingsothatShowishighlighted.
SelectingSafeZoneRingwillswitchthezoneringfromhidden
tovisible.
2.SelectSafeZoneRadius.
i.Selecttherequiredradiusforthesafezone.
3.SelectTimetoSafeZone.
i.Selecttherequiredtimeperiod.
4.SelectAISAlarmsothatOnishighlighted.
SelectingAISAlarmwillswitchthedangeroustargetalarm
betweenOnandOff.
3DDisplayOptions
Thefollowingoptionsareavailablewiththechartapplicationin3D
view:
CentreOfViewSwitchesacrosshaironandoffatthecentre
ofthescreenatsealevel.
ExaggerationAdjustingtheexaggerationhastheeffectof
verticallystretchingobjectsonthechart,makingiteasiertosee
theirshapeandposition.
TransducerConeSwitchesonandoffatransducercone
indicatingthecoverageofashndertransducer.
DepthScaleSwitchesonandoffadepthscaleatyourvessel
position.
Enablingcentreofview
Toenablethecentreofviewcrosshairatsealevelfollowthesteps
below:
In3Dview:
1.SelectMenu.
2.SelectPresentation.
3.SelectLayers.
4.Select3DDisplayOptions.
5.SelectCentreofViewsothatOnishighlighted.
Selectingcentreofviewwillswitchthecrosshaironandoff.
Adjustingthe3Dchartexaggeration
Inthe3Dchartview:
1.SelectMenu.
2.SelectPresentation.
3.SelectLayers.
4.Select3DDisplayOptions.
5.SelectExaggeration.
TheExaggerationnumericadjustcontrolisdisplayed.
6.Adjustthenumericadjustcontroltotherequiredsetting,between
1.0and20.0
7.UsetheRotaryControltoadjusttheexaggerationtothe
requiredsettingbetween1.0and20.0.
8.SelectOktoconrmsettingandclosethenumericadjustcontrol.
Enablingtransducercone
Toenablethetransducerconetoindicatethecoverageofyour
shndertransducerfollowthestepsbelow:
In3Dview:
1.SelectMenu.
2.SelectPresentation.
3.SelectLayers.
4.Select3DDisplayOptions.
5.SelectTransducerConesothatOnishighlighted.
SelectingTransducerconewillswitchthefunctiononandoff.
Enablingdepthscale
Toenableadepthindicatoratyourvesselslocationfollowthesteps
below:
In3Dview:
1.SelectMenu.
2.SelectPresentation.
3.SelectLayers.
4.Select3DDisplayOptions.
5.SelectDepthScalesothatOnishighlighted.
Selectingdepthscalewillswitchdepthindicatoronandoff.
2DChartUse
InadditiontonormalnavigationchartsFishmodeprovides
bathymetriccontourdataonthechartforuseduringshing.
Beforeyoucandisplaybathymetricdatainthechartapplicationyou
musthavechartcardswiththerelevantlevelofdetail.
Whenyouchangethe2DChartUsetotheFishoption,bathymetric
dataisshownonthechart(providingthatthechartcardcontains
bathymetricdataforthatparticularlocation).Certainchartdetailis
alsoremovedtoensurethebathymetricdatacanbeseenclearly
onthechartdisplay.
IfthechartcarddoesNOTcontainbathymetricdatathechart
revertstothedefaultNAV(navigation)data.
Note:Fishmodeisnotsuitablefornavigation.
Selectingshmode
Fromthechartapplication:
1.SelectMenu.
2.SelectPresentation.
3.Select2DChartUsesothatFishishighlighted.
Selecting2DchartusewillswitchthechartbetweenFishand
Navigationmodes.
Multiplechartsynchronization
Youcansynchronizetheheading,range,andpositioninformation
acrossmultiplechartviewsandnetworkeddisplays.
Whenchartsynchronizationisenabled:
Itisindicatedby“CHRTSync”inthechartapplicationtitlebar.
Anychangesmadetotheheading,rangeorpositioninanychart
instancewillbereectedinallotherchartinstances.
Note:Whenthe2Dand3Dchartviewsaresynchronized,the
MotionModeisalwaysRelativeMotion.
Synchronizingmultiplechartinstances
Fromthechartapplication:
1.SelectMenu.
2.SelectPresentation.
Usingthechart
119