14.18Sounderset–upmenuoptions
Thissectiondescribesthesettingsyoucanchangeusingthesoundersetupmenu:(Menu>Set-up>SounderSet-up).Thesetup
menucontainssettingsthatarelikelytobechangedinfrequently.
MenuItemDescriptionOptions
InternalSounderSwitchthebuiltinsonaronandoff,forusewhenyouhavemore
thanonemultifunctiondisplaywithinternalsonar.
Note:Disabledonnon-sonarvariants.
Note:MustbesettoOffifanexternalsonarisconnected.
•On
•Off
PingRateLimit
Providesaspeedlimiter;itisusefultoadjustthepingrateto
suitlocalconditions.Forexample,thepingratemaybetoo
fastwhenthereisahardbottominshallowwater.Theinternal
sonarrevertsto26pingspersecondwhenthesonarmodule
ispoweredoff.
Note:PingratelimitisdisabledifPingrateissettohyperin
thepresentationmenu.
•Internalsonar:5—50pingspersecond
•CHIRPsonar:5—80pingspersecond
PingEnableThesonarpingisnormallyenabled.Itcanbedisabled.Thisis
usefulwhenotherequipmentisbeingtested,orifsomeoneis
divingbeneaththeboat.ThissettingrevertstoEnabledwhen
thesonarmoduleispoweredoff.
•On
•Off
InterferencerejectionRemovesspikescausedbyothershnder-equippedvessels.
Note:InterferencerejectionwillbedisabledinHyperPing
mode
•Auto
•Low
•Medium
•High
2ndEchoIRAdjuststhepingrateinsmallincrements,accordingtothe2nd
echolevel.Thisresultsinbettersensitivityoftheimage.
Note:2ndEchoIRwillbedisabledinHyperPingmode
•Off
•Low
•High
SonarresetRestoreallsettingsonthesonarmoduletofactorydefault.When
performingasonarReset,itisnormaltobrieylooseconnection
withthesonarmodule.
•Yes
•No
TripCounterResetResetstheTripCounterofthesonarmodule
•Yes
•No
174