Operation Manual

Networkcableconnectortypes
Thereare2typesofnetworkcableconnectorSeaTalk
hs
and
RayNet.
SeaTalk
hs
connectorusedforconnecting
SeaTalk
hs
devicestoaRaymarinenetworkswitch
viaSeaTalk
hs
cables.
RayNetconnectorusedforconnecting
RaymarinenetworkswitchesandSeaTalk
hs
devicestothemultifunctiondisplayviaRayNet
cables.Alsorequiredforconnectingacrossover
couplerifonlyonedeviceisbeingconnectedto
thedisplay'sNetworkconnector.
Networkcabletypes
Thereare2typesofSeaTalk
hs
networkcable“patch”and
“network”.
PatchforconnectingthefollowingdevicestoaRaymarine
networkswitch:
ThermalcameraviaPoEinjector.
AdditionalRaymarinenetworkswitch.
PCorlaptopusingVoyagerplanningsoftware.
NetworkforconnectingthefollowingdevicestoaRaymarine
networkswitch:
SonarModule.
SR100Siriusweatherreceiver.
AdditionalcompatibleRaymarinemultifunctiondisplays.
RayNetconnectornetworkcables
CablePartnumber
1m(3.28ft)RayNettoSeaTalk
hs
(RJ45)cable
A62360
3m(9.84ft)RayNettoSeaTalk
hs
(RJ45)cable
A80151
10m(32.8ft)RayNettoSeaTalk
hs
(RJ45)cable
A80159
400mm(1.3ft)RayNettoRayNet
cable
A80160
2m(6.56ft)RayNettoRayNetcable
A62361
5m(16.4ft)RayNettoRayNetcable
A80005
10m(32.8ft)RayNettoRayNetcable
A62362
20m(65.6ft)RayNettoRayNetcable
A80006
50mm(1.97in)RayNet(male)to
RayNet(male)cable
A80162
400mm(1.3ft)RayNettoSeaTalk
hs
(female)adaptor
A80160
RayNetcablepuller5packR70014
SeaTalk
hs
networkcables
CablePartnumber
1.5m(4.9ft)SeaTalk
hs
networkcable
E55049
5m(16.4ft)SeaTalk
hs
networkcable
E55050
10m(32.8ft)SeaTalk
hs
networkcable
E55051
20m(65.6ft)SeaTalk
hs
networkcable
E55052
SeaTalk
hs
patchcables
CablePartnumber
1.5m(4.9ft)SeaTalk
hs
patchcable
E06054
5m(16.4ft)SeaTalk
hs
patchcable
E06055
CablePartnumber
10m(32.8ft)SeaTalk
hs
patchcable
E06056
15m(49.2ft)SeaTalk
hs
patchcable
A62136
20m(65.6ft)SeaTalk
hs
patchcable
E06057
Radarconnection
ThemultifunctiondisplayiscompatiblewithRaymarineNon-HD
digitalradomesandHD/SuperHDradarscanners.Thescanneris
connectedusingaSeaTalk
hs
cable.
Note:
NewcSeriesandNeweSeriesdisplays(excludingthee7
ande7D)canconnect2SeaTalk
hs
/RayNetdevicesdirectly
tothedisplay.
NewaSeriesandthee7/e7Ddisplayscanconnect1
SeaTalk
hs
/RayNetdevicedirectlytothedisplay.
TheradarisusuallyconnectedviaaRaymarinenetworkswitch.On
smallersystems(withonlyonedisplayandnootherdigitaldevices)
theradarmaybeconnectedtothedisplaydirectlyusingaSeaT alk
hs
crossovercoupler.
RadarconnectedusingRaymarinenetworkswitch
D12 2 5 2-1
3
2
1
4
6
7
5
1.Radarscanner.
2.Raymarinenetworkswitch.
3.RayNetcable.
4.RayNettoSeaTalk
hs
networkcable.
5.SeaTalk
hs
crossovercoupler
6.VCM(VoltageConverterModule)requiredforOpenArrays.
7.Powerconnection.
44
NewaSeries/NewcSeries/NeweSeries